background image

3. Installation Preparation.

4. Hanging Bracket Installation.

page 3

ON

OFF

ON

OFF

j-hook

hanging bracket

This fan can be mounted with a 

downrod

on a normal ceiling only. Fan 

cannot

 be mounted 

with flushmount installation 

nor

 on a vaulted 

ceiling.

Installation requires these tools:

Phillips screwdriver, flat-head screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

12f

t.

  - 15f

t.

12ft.  - 15ft.

(3.66m  - 4.57m)

(3.66m  - 4.57m)

10 feet

(3.05m)

(76cm)

30 

inches

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 10ft. (3.05m) from the floor and 30in. 
(76cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 225 
square feet (20.9 square meters). 

Turn off circuit breakers to current fixture from 
breaker panel and be sure operating light switch is 
turned to the OFF position. 

WARNING: 

Failure to disconnect power supply prior 

to installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be 

sure the outlet box is securely attached to the 
building structure and can support the full weight of 
the fan. Ensure it is clearly marked "Suitable for Fan 
Support." If not, it must be replaced with an approved 
outlet box. Failure to do so can result in serious injury.

CAUTION

Be sure oulet box is grounded properly 

and that a ground wire (green or bare) is present.

Install hanging bracket to outlet box using original 
screws, spring washers and flat washers  provided 
with new or original outlet box.

Install rubber 

cushions (if not already pre-attached to hanging 
bracket) between outlet box and j-hook hanging 
bracket to reduce vibration of metal to metal 
surfaces. Arrange electrical wiring to the front or 
back side of the hanging bracket.

*Note

It is very important that you use the proper 

hardware when installing the hanging bracket as this 
will support the fan. 

spring washers

outlet box screws

flat washers

downrod

installation

CANNOT be
installed on
angled or
vaulted ceilings

flushmount

installation

blade edge

rubber cushions

Summary of Contents for E-UB48BC4C1

Page 1: ...ly pg 6 Light Kit Assembly pg 7 Testing Your Fan pg 7 Troubleshooting pg 8 Parts Replacement pg 8 Warranty pg 8 net weight of fan 12 02 lb 5 45 kg E124404 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE PRINTED IN CHINA Federal regulations require all ceiling fans with light kits manufactured or imported after January 1 2009 to limit total wattage consumed by the light kit to 190W Therefore t...

Page 2: ...gauge house wire and two lead wires from the fan If your house wire is larger than 12 gauge or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL listed and marked suitable for use with the model fan you are instal...

Page 3: ...ned for repairs Check against parts inventory that all parts have been included a j hook hanging bracket 1 piece b blade 4 pieces c motor housing downrod and canopy pre assembled 1 piece d glass shade 1 piece e hardware pack page 2 b c d a e IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety bulb required 1 x 60 watt max candelabra base bulb include...

Page 4: ...y result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and can support the full weight of the fan Ensure it is clearly marked Suitable for Fan Support If not it must be replaced with an approved outlet box Failure to do so can result in serious injury CAUTION Be sure oulet box is grounded pr...

Page 5: ...e from rubber band Lift fan onto j hook hanging bracket and slide rubber bushing over hook Make the wiring connections as shown in Section 6 on the following page Important Find a secure attachment point wood ceiling joist highly recommended and secure safety cable refer to diagram on the following page as well Use a heavy duty wood screw washer and lock washer not supplied over safety cable loop ...

Page 6: ...referred to in the instructions below please use a qualified electrician Connect BLACK and BLUE wire from fan to BLACK wire from ceiling with wire connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wire connector provided If you intend to control the fan light w...

Page 7: ...on intact Note Do not remove center screw Lower blade over rubber cushion and attach with screws and washers that were previously removed Tighten screws securely Repeat with the remaining blades Lift canopy over hanging bracket until it touches the ceiling Tighten the canopy set screw to secure canopy page 6 blade canopy set screw canopy motor housing ...

Page 8: ...your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort Important Reverse switch must be set either completely to the LEFT or completely to the RIGHT for fan to function If the reverse switch is set in the middle position diagram 3 fan will not operate 10 Testing Your Fan glass shade pull chain extensions rubber ring thumbscrew 9 L...

Page 9: ...mance due to a defect in material or workmanship Contact Litex Customer Service at 1 800 527 1292 to arrange for return of fan Return fan shipping prepaid to Litex Industries Ltd We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY LITEX INDUSTRIES LTD will repair or replace at no charge to the original purchaser any fan motor that fails to operate ...