Troubleshooting.

Problem: 

Fan fails to operate.

Solutions:

1. Check wall switch to fan.
2. Verify that reverse switch is set completely in 
either direction.
3. Check to be sure fan is wired properly.

Problem: 

Fan wobbles.

Solutions:

1. Use the balancing kit in one of the hardware 
packs. 

If no blade balancing kit is provided, please 

call Customer Support, 1-800-527-1292, to request 
one.

2. Check to be sure set screw(s) on motor 
housing yoke is (are) tightened securely.
3. Check to be sure set screw on hanging ball is 
tightened securely.

LITEX LIFETIME LIMITED WARRANTY:
LITEX INDUSTRIES, LTD. warrants this fan to the original 
household purchaser for indoor use under the following 
provisions:
1-YEAR WARRANTY: LITEX INDUSTRIES, LTD. will replace or 
repair any fan which has faulty performance due to a 
defect in material or workmanship. Contact Litex Customer 
Service at 

1-800-527-1292

 to arrange for return of fan. 

Return fan, shipping prepaid, to Litex Industries, Ltd. We will 
repair or ship you a replacement fan, and we will pay the 
return shipping cost.
5-YEAR WARRANTY: LITEX INDUSTRIES, LTD. will repair or 
replace, at  no charge to the original purchaser, any fan 
motor that fails to operate satisfactorily when failure 
results from normal use.
RETURN FAN MOTOR ONLY, shipping prepaid, to Litex 
Industries. We will repair or ship purchaser a replacement 
motor and Litex will pay the return shipping cost.
6-YEAR to LIFETIME LIMITED WARRANTY: LITEX 
INDUSTRIES, LTD. will repair the fan, at no charge to the 
original purchaser for labor only, if the fan motor fails to 
operate satisfactorily when failure results from normal use. 
Parts used in the repair will be billed to the purchaser at 
prevailing prices at time of repair.
    The purchaser shall be responsible for all costs incurred 
in the removal, reinstallation and shipping of the product 
for repairs.
    This warranty does not apply when damage from 
mechanical, physical, electrical or water abuse results in 
causing the malfunction. Deterioration of finishes or other 
parts due to time or exposure to salt air is specifically 
exempted under this warranty.
    Neither Litex Industries nor the manufacturer will 
assume any liability resulting from improper installation or 
use of this product. In no case shall the company be liable 
for any consequential damages for breach of this, or any 
other warranty expressed or implied whatsoever. This 
limitation as to consequential damages shall not apply in 
states where prohibited.

Summary of Contents for DCF52BNK5

Page 1: ...3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 6 Blade Assembly pg 7 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 net weight of fan 12 54 lb 5 69 kg E89519 For Models DCF52BNK5 DCF52FBZ5 DCF52MWW5 Installation Guide READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE F P O F P O For Placement Only For Placement Only ...

Page 2: ...12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL listed and marked suitable for use with the model fan you are installing Switches must be UL general use switches Refer to the instructions p...

Page 3: ...fan need to be returned for repairs Check against parts inventory that all parts have been included 2 Parts Inventory a canopy 1 piece b hanging bracket pre attached to canopy 1 piece c 4in downrod and hanging ball with pin and clip 1 piece d motor housing 1 piece e blade arm 5 pieces f blade 5 pieces g hardware packs a IMPORTANT REMINDER You must use the parts provided with this fan for proper in...

Page 4: ...x using original screws spring washers and flat washers provided with new or original outlet box If installing on a vaulted ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the hanging bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as t...

Page 5: ...er downrod B the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of extended downrod and raise hanging ball Be sure stop pin aligns with slots on the inside of the hanging ball Tighten set screw securely Tip To prepare for threading electrical wires through downrod apply small piece of electrical tape to the ends of th...

Page 6: ...If there are only 3 screws in top of motor housing please proceed to next paragraph If there are 6 screws in top of motor housing remove every other screw and lock washer Thread wiring through canopy Place canopy over yoke aligning larger holes in canopy with the 3 existing screws in top of motor housing Insert the 3 screws and 3 lock washers that had been removed if there were only 3 screws locat...

Page 7: ...t electrical wiring can be made as follows Connect BLACK wire from fan to BLACK wire from ceiling with wire connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wire connector provided Since this fan does not come with a light kit you will need to cap off the BLUE...

Page 8: ...ewdriver Repeat for the remaining blades Remove blade arm screws and lock washers from underside of motor If plastic motor locks are installed with blade arm screws discard plastic motor locks save blade arm screws and lock washers to secure blade arms Align blade arm holes with motor screw holes and attach blade arm with lock washers and blade arm screws Before securing screws permanently repeat ...

Page 9: ...ice Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season DOWN position in summer diagram 1 UP position in winter diagram 2 A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort Important Reverse switch must be set either comple...

Page 10: ...TY LITEX INDUSTRIES LTD will repair or replace at no charge to the original purchaser any fan motor that fails to operate satisfactorily when failure results from normal use RETURN FAN MOTOR ONLY shipping prepaid to Litex Industries We will repair or ship purchaser a replacement motor and Litex will pay the return shipping cost 6 YEAR to LIFETIME LIMITED WARRANTY LITEX INDUSTRIES LTD will repair t...

Page 11: ...empaquetado del ventilador Pág 2 Inventario de piezas Pág 2 Preparación para la instalación Pág 3 Instalación del soporte de montaje Pág 3 Ensamblaje del ventilador Págs 4 5 Instalación eléctrica Pág 6 Colocación de la cubierta decorativa Pág 6 Colocación de las aspas Pág 7 Verificación del funcionamiento del ventilador Pág 8 Localización de fallas Pág 9 Piezas de repuesto Pág 9 Garantía Pág 9 F P...

Page 12: ...Si el calibre del cable de la casa es superior al 12 o hay más de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tamaño correcto de conectores para cable que se debe usar 5 Los diagramas eléctricos son únicamente para referencia Los juegos de luz que no se incluyen con el ventilador deben...

Page 13: ...or con el inventario de piezas y verificar que se incluyeron todas página 2 2 Inventario de piezas a cubierta decorativa 1 unidad b soporte de montaje fijado de antemano a la cubierta decorativa 1 unidad c tubo de 10 16cm y bola que sirve para colgar con perno y clavija 1 unidad d bastidor del motor 1 unidad e brazo para el aspa 5 unidades f aspa 5 unidades g paquetes de artículos de ferretería RE...

Page 14: ... de salida y asegurarse de que el interruptor de luz esté APAGADO ADVERTENCIA El no desconectar el suministro de fuerza antes de la instalación puede tener por resultado lesiones graves Quitar el aparato existente ADVERTENCIA Si utiliza una caja de salida eléctrica existente asegurarse de que la caja de salida esté firmemente conectada a la estructura del edificio y que sea capaz de sostener el pe...

Page 15: ...l agujero para el tornillo de fijación en ese extremo usar ese agujero al colocar el tornillo de fijación Introducir el perno de tope en la parte de arriba del tubo más largo y subir la bola que sirve para colgar Asegurarse de que el perno de tope se ponga en línea con las ranuras dentro de la bola que sirve para colgar Apretar bien el tornillo de fijación Sugerencia Para preparar los cables para ...

Page 16: ...ornillos Para preparar el ventilador para hacer la instalación eléctrica colgar el ventilador en el soporte de montaje colocando la cubierta decorativa en la parte saliente del soporte de montaje Usar uno de los agujeros que no tenga ranura en el borde de la cubierta decorativa para hacerlo Ya que esté sujetado el soporte de montaje a la caja de salida y capaz de apoyar el ventilador usted está li...

Page 17: ...ntilador esté sujetado en el soporte de montaje se puede hacer la instalación eléctrica como sigue Conectar el cable NEGRO del ventilador al cable NEGRO que sale del techo con un conector para cable provisto Conectar el cable BLANCO del ventilador al cable BLANCO del techo con un conector para cable provisto Conectar todos los conductores a TIERRA VERDES del ventilador a los PELADOS VERDES del tec...

Page 18: ... el aspa y las arandelas de seguridad del lado inferior del motor Si se han instalado soportes de plástico con los tornillos para el brazo para el aspa desechar los soportes de plástico guardar los tornillos para el brazo para el aspa y las arandelas de seguridad para asegurar los brazos para el aspa Alinear los agujeros de uno de los brazos para las aspas con los agujeros para los tornillos en el...

Page 19: ...es de comunicarse con el Servicio al Cliente Apagar el ventilador completamente antes de mover el interruptor de reversa Regularlo para que se circule bien el aire dependiendo de las estaciones del año posición ABAJO en verano diagrama 1 posición ARRIBA en invierno diagrama 2 Un ventilador de techo le permitirá subir el termostato en verano y bajarlo en invierno sin notar una diferencia en su como...

Page 20: ...ador Devolver el ventilador con los gastos de envío prepagados a Litex Industries Ltd Nosotros repararemos o reemplazaremos el ventilador y pagaremos los gastos de envío de regreso GARANTIA DE 5 AÑOS LITEX INDUSTRIES LTD reemplazará o reparará sin costo al comprador original cualquier motor de ventilador que no funcione de manera satisfactoria a causa de uso normal DEVOLVER EL MOTOR SOLAMENTE los ...

Reviews: