background image

page 6

8. Canopy Assembly.

7. Wiring.

black

black

from fan

from ceiling

white

white

blue

black supply wire

ground

(green

or bare)

white supply wire

CAUTION

Be sure outlet box is properly grounded 

and that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with 
Local Codes or Ordinances and the National 
Electrical Code. If you are unfamiliar with electrical 
wiring or if the house/building wires are different 
colors than those referred to below, please use a 
qualified electrician.

When downrod is secured in place on the 
hanging bracket, electrical wiring can be made 
as follows:
Connect 

BLACK

 and 

BLUE

 wire from fan to 

BLACK

 wire from ceiling with wire connector 

provided. 
Connect 

WHITE

 wire from fan to 

WHITE

 wire 

from ceiling with wire connector provided. 
Connect all 

GROUND 

(

GREEN

) wires together 

from fan to 

BARE

/

GREEN

 wire from ceiling with 

wire connector provided.

If you intend to control the fan light with a 
separate light switch, connect 

BLUE

 wire from 

fan to the 

BLACK

 supply from the independent 

switch.

* Wrap each wire connector separately with 
electrical tape as an extra safety measure.

*

ground 
(green or bare)

Raise canopy to hanging bracket, aligning 
slotted holes in canopy with loosened screws 
in hanging bracket. Twist canopy to lock. 
Insert screws (along with star washers) 
previously removed (on page 3, Section 4) 
and secure all screws with a Phillips 
screwdriver.

canopy

hanging bracket

This fan is remote control adaptable 
(remote control sold separately).

Summary of Contents for VN52

Page 1: ... 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 6 Blade Assembly pg 7 Light Kit Assembly Optional pgs 7 8 Testing Your Fan pg 9 Troubleshooting pg 10 Parts Replacement pg 10 Warranty pg 10 net weight of fan 17 22 lb 7 81 kg E124404 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE PRINTED IN CHINA ...

Page 2: ... gauge or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL listed and marked suitable for use with the model fan you are installing Switches must be UL general use switches Refer to the instructions packaged with...

Page 3: ...ter 1 piece j glass shade 1 piece k hardware packs page 2 Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that all parts have been included IMPORTANT REMINDER You must use the pa...

Page 4: ...ing Bracket Installation blade edge Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and c...

Page 5: ... downrod apply a small piece of electrical tape to the ends of the electrical wires this will keep the wires together when threading them through the downrod Loosen yoke set screws and nut at top of motor housing Remove pin and clip from downrod if you have not already done so Slide downrod through canopy Thread electrical wires through downrod and pull extra wire slack from the upper end of the d...

Page 6: ...holes are larger than the rest of them If there are only 3 screws in top of motor housing please proceed to next paragraph If there are 6 screws in top of motor housing remove every other screw and lock washer Thread wiring through canopy Place canopy over yoke aligning larger holes in canopy with the 3 existing screws in top of motor housing Insert the 3 screws and 3 lock washers that had been re...

Page 7: ... to BLACK wire from ceiling with wire connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wire connector provided If you intend to control the fan light with a separate light switch connect BLUE wire from fan to the BLACK supply from the independent switch Wrap e...

Page 8: ...l 3 screws with a Phillips screwdriver Light Kit Assembly continued on next page 9 Blade Assembly WARNING To reduce the risk of serious bodily injury DO NOT use power tools to assemble the blades If overtightened blades may crack and break Time Saver Washers for blade screws can be set on each blade screw prior to installing blades Locate 15 blade attachment screws and washers in one of the hardwa...

Page 9: ...h hole in finial and secure glass shade to light kit fitter by tightening finial Do NOT overtighten finial as glass may crack or break If you wish to use your fan WITHOUT the light kit remove hex nut and lock washer from threaded rod at top of light kit fitter Unscrew switch housing cap to remove it from the light kit fitter Then gently feed BLACK and WHITE wires from light kit fitter through hole...

Page 10: ...ues before contacting Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season DOWN position in summer diagram 2 UP position in winter diagram 3 A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort Important Rever...

Page 11: ...ce or repair any fan which has faulty performance due to a defect in material or workmanship Contact Litex Customer Service at 1 800 527 1292 to arrange for return of fan Return fan shipping prepaid to Litex Industries Ltd We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY LITEX INDUSTRIES LTD will repair or replace at no charge to the original pu...