Litex Industries UBW48ABZ4L Installation Manual Download Page 8

page 7

It is recommended that you test fan before 
finalizing installation. Restore power from circuit 
box and light switch (if applicable). Test fan 
speeds with the pull chain labeled FAN. Start at 
the OFF position (no blade movement). First pull 
will set the fan to HI. Second pull will set the fan 
to MEDIUM. Third pull will set the fan to LOW. 
Fourth pull will again set the fan to the OFF 
setting. Test light with the pull chain labeled 
LIGHT. (

diagram 1

) If fan and/or light do (does) 

not function, please refer to "Troubleshooting" 
section to solve any issues before contacting 
Customer Service.

 
Turn fan completely off 

before

 moving the 

reverse switch. Set reverse switch to recirculate 
air depending on the season:
 

- LEFT position in summer (

diagram 2

)

 

- RIGHT position in winter (

diagram 3

)

A ceiling fan will allow you to raise your 
thermostat setting in summer and lower your 
thermostat setting in winter without feeling a 
difference in your comfort.

 

Important

: Reverse switch must be set either 

completely to the LEFT

 or 

completely to the RIGHT

 

for fan to function. If the reverse switch is set in 
the 

middle

 position (

diagram 4

), fan will not 

operate.

 
Attach pull chain extensions supplied or custom 
pull chain extensions (sold separately) to the end 
of the pull chains.

10. Testing Your Fan.

glass shade

pull chain
extensions

rubber ring

thumbscrew

9. Light Kit Assembly.

Install 1 medium base 6.5 watt max. LED 
bulb (included).

IMPORTANT

: When replacing bulb, 

please allow bulb and glass shade to 
cool before touching.

Partially loosen 3 thumbscrews at 
bottom of motor housing and raise glass 
shade to motor housing. Secure glass 
shade with thumbscrews. Be sure 
thumbscrews make contact with rubber 
ring on glass shade, 

but do not 

overtighten thumbscrews as glass may 
crack or break

reverse switch

bulb

motor

housing

diagram 2

diagram 3

diagram 4

diagram 1

Summary of Contents for UBW48ABZ4L

Page 1: ...llation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pg 4 Wiring pg 5 Canopy Assembly pg 6 Blade Assembly pg 6 Light Kit Assembly pg 7 Testing Your Fan pg 7 Troubleshooting pg 8 Par...

Page 2: ...ne 12 gauge house wire and two lead wires from the fan If your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electri...

Page 3: ...his fan need to be returned for repairs Check against parts inventory that all parts have been included a hanging bracket 1 piece b blade 4 pieces c motor housing downrod and canopy pre assembled 1 pi...

Page 4: ...sconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building s...

Page 5: ...lt in serious injury or death Tip Seek the help of another person to hold the stepladder in place and to lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceili...

Page 6: ...d BLUE wire from fan to BLACK wire from ceiling with wire connector provided Connect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together...

Page 7: ...ment screws along with washers from topside Tighten all 4 screws securely Repeat procedure with remaining blades Locate 1 rubber cushion at the top of the motor housing Remove the 2 larger screws do n...

Page 8: ...our thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort Important Reverse switch must be set either completely to the LEFT or complete...

Page 9: ...acement fan and we will pay the return shipping cost 5 YEAR WARRANTY LITEX INDUSTRIES LTD will repair or replace at no charge to the original purchaser any fan motor that fails to operate satisfactori...