LiteOn PF-2123-2 Startup Manual Download Page 7

 

STARTUP GUIDE 

PF-2123-2, PF-2223-1 

10-Slot Power Supply System 

 

PF-2223-1-ST-02 

Page 7 of 10

 

July 2015 

3-Phase, 4-Wire System (without neutral) 

PF-2223-1L1N – 10 slot single input 

PF-2123-2LNN – 5+5 slot single input 

PF-2223-1LDN – 10 slot dual input 

L1–L2 

L2–L3 

L3–L1 

208VAC 

208VAC 

208VAC 

208VAC 

220VAC 

220VAC 

220VAC 

220VAC 

230VAC 

230VAC 

230VAC 

230VAC 

240VAC 

240VAC 

240VAC 

240VAC 

 

3.

 

After verifying the input power connector has been wired correctly, disconnect power from the 

connector by turning off its upstream circuit breaker. 

Shelf Power Activation 

After the wiring to the input power connector has been tested and verified, it can be plugged into and 
secured to the Power Shelf. 

To secure the input power connector and activate the Power Shelf: 

1.

 

Using a DMM, verify that power is disconnected from the input power connector. 

2.

 

Insert the wired connector into the input connector of the Power Shelf and secure the connector 

in place by torqueing the screws to 4 N-m (3.0 ft-lbs) with a T-20 star driver. 

3.

 

Activate electrical power to the Power Shelf via its circuit breakers. The Power Shelf is activated 

and ready for testing. 

C13 Voltage Tests 

Verify that the Power Shelf has the correct voltage on the C13 receptacles as shown in the table below. 

 

C13 Receptacles 

(as viewed from rear of Power Shelf) 

Phase A Input Power 

Left three C13 receptacles (same voltage as Phase A) 

Phase B Input Power 

None 

Phase C Input Power 

Right three C13 receptacles (same voltage as Phase C) 

 

To verify correct voltage on the C13 receptacles: 

 

With a DMM, verify that the C13 receptacles have power. As shown below, Phase A (L1) power 

should be available on the left side C13 receptacles and Phase C (L3) power should be available on 

the right side C13 receptacles. 

Summary of Contents for PF-2123-2

Page 1: ...3 Phase 10 Slot Power Supply System STARTUP GUIDE PF 2223 1 ST 02 Page 1 of 10 July 2015...

Page 2: ...any errors or omissions contained in this document All content is provided As Is and As Available Lite On reserves the right to correct errors or omissions in this document Other brand names mentioned...

Page 3: ...ces These compact PSUs provide 2 5kW 12 5V 200A for main power output and 30W 12V 2 5A for standby power applications In addition they support PMBUS 1 2 with boot loader LED status indicators and circ...

Page 4: ...eam circuit breaker must be easily accessible The unit must be disconnected from AC power source by opening this circuit breaker WARNING Do not connect power to the 22 5kW Power System until all condi...

Page 5: ...nnects only to a circuit provided with branch circuit overcurrent protection in accordance with the National Electric Code ANSI NFPA 70 The upstream circuit breaker must be easily accessible The unit...

Page 6: ...slot single input PF 2123 2LNM 5 5 slot single input PF 2223 1LDM 10 slot dual input L1 L2 L2 L3 L3 L1 380VAC 380VAC 380VAC 380VAC 400VAC 400VAC 400VAC 400VAC 415VAC 415VAC 415VAC 415VAC PF 2223 1L1M...

Page 7: ...hat power is disconnected from the input power connector 2 Insert the wired connector into the input connector of the Power Shelf and secure the connector in place by torqueing the screws to 4 N m 3 0...

Page 8: ...rational If both lights do not illuminate green on the PSU contact Lite On Power Systems technical support before proceeding 2 Using a DMM verify that the output voltage is 12 5VDC on all three output...

Page 9: ...helf Datasheet For information about the 2 5kW Power Supply Unit refer to the Lite On 2 5kW Power Supply Unit Datasheet For instructions on installing and using the 3 Phase 22 5kW Power Supply System...

Page 10: ...074 1 469 331 9838 www liteon pss com email pss sales liteon com Lite On Power System Solutions No 90 Chien 1 Rd Chung Ho Dist New Taipei City 23585 Taiwan 886 2 2226181 ext 5026 www liteon pss com em...

Reviews: