LiteOn EVO6-DBU-43D7 User Manual Download Page 5

 

 

F.

 

Specifications 

Voltage 

400V 

200V 

Model Name 

EVO6-DBU-

41D5 

EVO6-DBU-43D7 

EVO6-DBU-

21D5 

EVO6-DBU-

23D7 

Output Rating 

Max. Motor Capacity (KW) 

1.5 

3.7 

1.5 

3.7 

Max. Discharge Current (A) 10%ED 

1.8 

3.5 

16 

Braking Start-up Voltage (V

DC

660

690

720

750

780  330

345

360

375

390 

Input Rating 

DC Voltage(V

DC

400~780 

200~390 

Protection 

Braking Torque 

150%   

Braking Usage Rate 

10%ED   

Overheat Protection 

Braking unit Overheat Alarm (95

Power Charge Display 

The Main circuit voltage is extinguished below PN 50V

DC 

 

Overheat Alarm Output 

Relay Output (250V

AC

 , under 1A; 30V

DC

 , under 1A) 

Environment 

Installation Location 

Indoor (no corrosive gases, metallic dust) 

Operation Temperature 

−10

  ~ +50

 

Storage Temperature 

−20

  ~ +60

 

Humidity 

Less than 90%R.H. Non-condensing 

Vibration 

9.8m/s

2

 (1G) under 20Hz, 2m/s

2

 (0.2G) at 20~50Hz 

Mechanical 

Dimension (W*H*D) 

47*123*79.5mm 

Installation Method 

Rail / Screw 

Protection Level 

IP20 

Material 

Plastic (similar with EVO 6000) 

 

 

 

 

 

Summary of Contents for EVO6-DBU-43D7

Page 1: ...ety because the input terminals of the braking unit and braking resistor are filled with high voltage Make sure to fully tighten screws when installing C Wiring Notice Do not proceed with wiring while...

Page 2: ...2 D EVO 6 DBU Design D 1 440V Power Input Terminal Fault Lamp Power Lamp Brake Lamp Input Voltage Setting Switch Master Slave Terminal Relay Output Terminal Master Slave Switch Brake Resistor Terminal...

Page 3: ...3 D 1 220V Power Input Terminal Fault Lamp Power Lamp Brake Lamp Input Voltage Setting Switch Master Slave Terminal Relay Output Terminal Brake Resistor Terminal Master Slave Switch...

Page 4: ...4 E Dimensions Unit mm...

Page 5: ...te 10 ED Overheat Protection Braking unit Overheat Alarm 95 Power Charge Display The Main circuit voltage is extinguished below PN 50VDC Overheat Alarm Output Relay Output 250VAC under 1A 30VDC under...

Page 6: ...g resistor has better be installed in individual metallic box with forced air cooling Connect the ground terminal to the Earth Ground 230V followers the third grounding construction 460V followers the...

Page 7: ...G 3 Multiple installation master slave parallel G 4 Terminal Wire Gauge Terminal AWG kcmil mm 2 Screw Suggestion Available Suggestion Available P N B1 B2 10 14 8 2 58 1 63 3 26 M3 M1 M2 S1 S2 RA RB RC...

Page 8: ...ltage input users need to set on the braking unit switch and this setting will affect the braking unit action level Below shows more details Input voltage dip switch 400V class AC Power Starting Volta...

Page 9: ...r Resistor Value Spec Resistor Quantity HP kW 460V 0 5 0 4 300W 400 1 1 0 75 300W 400 1 2 1 5 400W 300 1 3 2 2 600W 200 1 5 3 7 900W 120 1 230V 0 25 0 2 200W 250 1 0 5 0 4 200W 250 1 1 0 75 200W 150 1...