LiteOn EVO6-DBU-43D7 User Manual Download Page 1

 

 

EVO6000 Braking Modules│User Manual 

A.

 

Preface 

EVO6-DBU are applied to absorb the motor regeneration energy when the three phase 

AC  motor  stops  by  deceleration.  With  EVO6-DBU,  the  regeneration  energy  will  be 

dissipated  in  dedicated  braking  resistors.  To  prevent  mechanical  or  human  injury, 

please refer to this user manual before installing.   

B.

 

Safety   

 

Do not use or install damaged braking unit or any braking unit without complete 

components inside.

 

 

When using the product, please hold the outer casing of the product. Do not only 

take the product cover to move it. 

 

Please pay attention to safety because the input terminals of the braking unit and 

braking resistor are filled with high voltage. 

 

Make sure to fully tighten screws when installing. 

C.

 

Wiring Notice 

 

Do not proceed with wiring while power is applied to the circuit. 

 

The wiring gauge and distance must comply with the electrical code. 

 

The + (P),

 

- (N) terminals of the AC motor drive (EVO6000 series), connected to 

the  braking  unit, must  be  confirmed for  correct polarity  lest  the drive  and the 

braking unit be damaged when power on. 

 

When the braking unit performs braking, the wires connected to the + (P),- (N),B1 

and  B2  would  generate a  powerful electromagnetic  field  for  a  moment due  to 

high current passing through. These wires should be wired separately from other 

low voltage control circuits less they make interference or mis-operation. 

Summary of Contents for EVO6-DBU-43D7

Page 1: ...ety because the input terminals of the braking unit and braking resistor are filled with high voltage Make sure to fully tighten screws when installing C Wiring Notice Do not proceed with wiring while...

Page 2: ...2 D EVO 6 DBU Design D 1 440V Power Input Terminal Fault Lamp Power Lamp Brake Lamp Input Voltage Setting Switch Master Slave Terminal Relay Output Terminal Master Slave Switch Brake Resistor Terminal...

Page 3: ...3 D 1 220V Power Input Terminal Fault Lamp Power Lamp Brake Lamp Input Voltage Setting Switch Master Slave Terminal Relay Output Terminal Brake Resistor Terminal Master Slave Switch...

Page 4: ...4 E Dimensions Unit mm...

Page 5: ...te 10 ED Overheat Protection Braking unit Overheat Alarm 95 Power Charge Display The Main circuit voltage is extinguished below PN 50VDC Overheat Alarm Output Relay Output 250VAC under 1A 30VDC under...

Page 6: ...g resistor has better be installed in individual metallic box with forced air cooling Connect the ground terminal to the Earth Ground 230V followers the third grounding construction 460V followers the...

Page 7: ...G 3 Multiple installation master slave parallel G 4 Terminal Wire Gauge Terminal AWG kcmil mm 2 Screw Suggestion Available Suggestion Available P N B1 B2 10 14 8 2 58 1 63 3 26 M3 M1 M2 S1 S2 RA RB RC...

Page 8: ...ltage input users need to set on the braking unit switch and this setting will affect the braking unit action level Below shows more details Input voltage dip switch 400V class AC Power Starting Volta...

Page 9: ...r Resistor Value Spec Resistor Quantity HP kW 460V 0 5 0 4 300W 400 1 1 0 75 300W 400 1 2 1 5 400W 300 1 3 2 2 600W 200 1 5 3 7 900W 120 1 230V 0 25 0 2 200W 250 1 0 5 0 4 200W 250 1 1 0 75 200W 150 1...

Reviews: