![LITEMAX ALF2011 Manual Download Page 14](http://html1.mh-extra.com/html/litemax/alf2011/alf2011_manual_1928169014.webp)
Page 14
Test tem
Test Condition
Remark
High temperature storage 60
℃
, 240Hrs
Note 1, 2, 3
Low temperature storage
-20
℃
, 240Hrs
Note 1, 2, 3
High temperature operation 50
℃
, 240Hrs
Note 1, 2, 3
Low temperature operation 0
℃
, 240Hrs
Note 1, 2, 3
Temperature cycling
(non-operation)
-20
℃
~60
℃
1H, 10mins, 1H, 5cycles
Note 1, 2, 3
Electrostatic discharge
(non-operation)
150 pF,150
Ω
,10kV,1 second, 9 position on
the panel, 10 times each place
Note 3
Vibration (non-operation)
Sweep:1G, 10H
Z
~ 500H
Z
~ 10H
Z
/2.5min 2
hours for each direction X, Y, Z (6 Hrs in total)
Note 1, 2, 3
Mechanical shock
(non-operation)
50G/11ms, 200G/2ms,
±
X,
±
Y,
±
Z once for
each direction
Note 1, 2, 3
Note (1) Evaluation should be tested after storage at room temperature for one hour.
Note (2) here should be no change which might affect the practical display function
when the display quality test is conducted under normal operating condition.
Note (3) Judgment:
1.Function OK.
2.No serious image quality degradation.
Summary of Contents for ALF2011