3A. If the U-bracket is fastened to UBMP through its screw hole #1 & 4, the U-bracket or the light body can be rotated as per 
Figure 3. Fasten M8 screws at 20 N.M. torque after the needed tilting angle is adjusted to correct position

Lumen output from

the optic side

Installation Platform

2B. To rotate the U-bracket towards the heatsink/junction box side of the LED luminaire (the rotation range is 0° to 90°), place 
two pieces of check washers onto screw hole 2 & 3 (see Figure 4) of UBMP, fasten the U-bracket and the round plate through the 
middle screw hole of UBMP using 1 piece of Hex head screw (M8) properly, then fasten the U-bracket using another two pieces of 
screws (M8) through screw hole 2 & 3 properly (not too tight to rotate the U-bracket / light body).

Screw hole 2

Screw hole 3

90°

U-bracket 

mounting piece

PROCEED to 3B

3B. If the U-bracket is fastened to UBMP through its screw hole #2 & 3, the U-bracket or the light body can be rotated as per 
Figure 5. Fasten M8 screws at 20 N.M. torque after the needed tilting angle is adjusted to correct position.