![Litelume Autolume Series Installation Instructions Download Page 1](http://html1.mh-extra.com/html/litelume/autolume-series/autolume-series_installation-instructions_1928164001.webp)
Autolume Series Area Light
Installation Instructions
LITELUME™ seeks to deliver the most advanced and efficient LED technology. Due to
technology progression, specifications may change. We reserve the right to update product
specifications without notice. Contact LITELUME™ for the most up-to-date data.
www.litelume.com
[email protected]
833.LED.LUME
Page 1/4
Rev Date: 08/20/2018
©Lite Lume Corporation 2018
Important Information
1. Normal operating environment and temperature: -40ºC to +50ºC. Fixtures is suitable for Airport, Car Dealerships, Architectural,
Factory, Warehouse, High Mast lighting and stadium lighting. The installation should be performed by qualified electricians or
lighting technicians.
2. Before commencing installation or maintenance, ensure electricity is switched off at the mains. Installation or maintenance
should be carried out by a qualified electrician.
3. The luminaire must not, under any circumstances, be installed directly to flammable materials, and luminaires must not be
covered with any flammable materials.
4. Mounting height range of 0 to 15 meters, this model is suitable for outdoor and indoor use.
5. Ensure there is adequate free air circulation of at least 50cm around the luminaire. All luminaires run hot. It is the installer’s
responsibility to consider fire risk and take appropriate precautions.
Large Yoke Installation
1.Bring the assembled LED luminaire out of its packaging carton, disassemble it as per Figure 1. Get the mains cable through
the round hole at the middle of the U-bracket, connect the light body with mains supply, then fix the U-bracket to ground, wall,
ceiling, pole, or other platform.
If it’s not necessary to fix the U-bracket first of all, but fix the whole fixture directly to the installation platform, do not disassemble
the fixture.
Check washer
Hex head screws
U-bracket mounting piece
U-bracket
Round plate
2A. To rotate the U-bracket towards the optic side of the LED luminaire (the rotation range is -90° to 0°), place two pieces of check
washers onto screw hole 1 & 4 (see Figure 2) of U -bracket mounting piece (UBMP), fasten the U-bracket and the round plate
through the middle screw hole of UBMP using 1 piece of Hex head screw (M8) properly, then fasten the round plate and U-bracket
to UBMP using another two pieces of screws (M8) through screw hole 1 & 4 properly (not too tight to rotate the U-bracket / light
body).
.
Screw hole 1
Screw hole 4
U-bracket
mounting piece
90°
PROCEED to 3A