Litelink VAT-1001 Operating Instructions Download Page 2

Installation Instructions 

The diagram below shows the typical installation of the VAT-1001 and 
VAR-1001 fiber optic video/audio transmission units.  Both should be 
connected as shown and a video signal applied to the transmitter. To 
compensate for the unique fiber optic losses of your installation there 
is a level adjustment on the VAR-1001.  The receiver video Level 
adjustment should then be set for a 1 Volt pp video output signal, or 
for an acceptable picture.  The range of the receiver level control is 
adequate to allow the full 0-13dB optical path loss range to be 
accommodated.  The audio channels do not require any adjustments. 

 

 

Indicator Lights 

Indicator Lights 

when 

 

Pwr 

Proper power is present. 

Alrm 

The loss of video alarm is activated and there is 
no video present 

Vat 

Internal circuitry is OK.  

Var 

A fiber optic link is present 

Video 

A Video signal is being transmitted or received. 

 

Power Terminal Block Connections 

Pin Function 

Alarm output for use with optional Alarm Sensing Unit 
ALM-1000. No other connections should be made to this 
terminal 

+11 to 24 DC or AC Volts input 

AC or DC return (Common to Housing) 

Be certain to check all connections, settings and voltages before 
applying 

power 

 

         106117 

Rev 

 

Audio Removable Terminal Block Connections 

Pin Function 

Signal Channel 1 +

 

Signal Channel 1  -- 

Ground (common to housing) 

Signal Channel 2  -- 

Signal Channel 2 + 

The audio input and output are transformer coupled and may be used 
in either a balanced or an unbalanced configuration.   
 
Balanced input or output: 

Connect audio to Pin 1 and 2.  (4 & 5 for channel 2) 
Pin 3 is then used as a shield or unconnected. 

Unbalanced input or output: 

Connect audio signal to Pin 1 (5 for channel 2).   
Connect audio return (and/or shield) to Pin 2 (4 for channel 2). 
Connect jump Pin 2 (4 for channel 2) to Pin 3 (ground). 

 

In both cases be certain that the audio input level does not exceed 1-
Volt RMS (3 volts peak-to-peak) or distortion and/or clipping will 
occur. 

 

Alarm Switch 

The 

Alarm

 is used to turn the video alarm function on and off.  This is 

utilized when the Alarm sensing unit, ALM-1000 is being utilized. 

 
Note that when there is a loss of signal carrier, usually due to broken 
fiber or excessive optical path loss, the Alarm indicator will light and 
the Link indicator will go off.  The alarm switch cannot disable the 
function of the indicator lights. 

 
 
 

VAT-1002-

VAR-1002-

Power

Alarm

Power

Alarm

Fiber Optic Cable

Video Input

Video Output

Power

Power

Level Adjust

Video

Alarm Switch

Video

Audio Input

Audio Output

Link

Link

Alarm Switch

Typical Fiber Optic CCTV System

Fiber Optic Cable

Camera

Monitor

ALM-1000

Alarm

Contacts

Audio

line-level

Mic(line level)

VAR-1000

VAT-1000