Litelink RSW-1002 Operating Instructions Download Page 2

Installation Instructions 

 

The diagram below shows the typical installation of the RSW-1002 
with VT-1001 and VR-1001 fiber optic video transmission units.   
 
 

Upon loss of the primary video signal, the RSW-1002 will 
automatically switch the remaining secondary (backup) video signal to 
the output as well as activate the front panel alarm “Alm” indicator 
and ALM-1000 Alarm Sensing Unit if used.      

 
 
 
 
 
 

Power Terminal Block Connections 
 

Pin Function 

Alarm output for use with optional Alarm Sensing Unit 
ALM-1000. No other connections should be made to this 
terminal 

+11 to 24 DC or AC Volts input 

AC or DC return (Common to Housing) 

 

Be certain to check all connections, settings and voltages before 
applying power  

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

108515 Rev E

 

 

Mode Switch 

 

Setting Function 

Pri 

Forces Primary feed to common output 

Auto 

Auto mode;   

If there is no signal on primary feed, but a signal 
on the secondary feed, the secondary feed is 
connected to common output.  Otherwise, 
Primary feed connects to common output. 

Sec 

Forces Secondary feed to common output 

 

Indicator Lights 
 

Indicator Lights 

when 

 

Pwr 

Proper power is present. 

Alrm* 

One or both video input signals are not present 

Pri 

A signal is present at Primary input 

Sec 

A signal is present at Secondary input. 

Fault 

The loss of the signal at Input 1 (Primary) has 
occurred and the video signal at Input 2 (Backup) 
has been routed to the output. 

 

 * Note that if the alarm “Alm” indicator is enabled the output for the 
optional ALM-1000 Alarm Sensing Unit will also be enabled. 
 

5 Pin Control Terminal Block Connector Block 

 

Pin Function 

Relay contacts 

(2 Amp dry contact)

 

Normally Open Contact    

2 Common 

Contact 

3 Normally 

Closed 

Contact 

External control of Mode (valid only when in Auto mode) 

Ground to Force Primary output 

Ground to Force Secondary output 

 

 

 
 
 

Typical Redundant Fiber Optic CCTV System

Fiber Optic Cable

Camera

Monitor

VT-1001

VR-1001

ALM-1000

Alarm

Contacts

RSW-1002

Camera

VT-1001

VR-1001

Fiber Optic Cable

Reviews: