Litelink RSW-1002 Operating Instructions Download Page 1

WARRANTY 

 

All fiber optic transmission systems, products and accessories 
manufactured by Liteway, Inc. and it’s subsidiaries are fully tested 
prior to shipment and are warranted against defective materials 
and workmanship for a period of five full years from the date of the 
original shipment.  Should a problem occur, a Return Material 
Authorization Number (RMA) must be obtained from Liteway Inc. 
at (516) 931-2800 and the item returned to Liteway, Inc. 166 
Haverford Road, Hicksville, NY 11801, USA, prepaid.  Liteway Inc. 
will then, at its option repair or replace the defective item. 
 
Liteway, Inc. maximum liability under this warranty is limited to the 
cost of the defective item only.  No contingent liabilities of any kind 
are either assumed or implied. 
 
Any items returned to Liteway, Inc. that have been misused, 
abused, damaged, modified, connected or adjusted in any way 
contrary to the instructions furnished by Liteway, Inc. or repaired 
by unauthorized personnel will not be covered by this warranty.  
Any non-warranty repairs required will be quoted at the current 
rate for such services. 

 
 

Important Notices 

 

CAUTION !

   AVOID DIRECT EXPOSURE TO BEAM. 

All –5, -7, -8, and -9 Models use laser diodes. These solid-state 
laser diodes are located in the optical ports of these units.  Laser 
diodes produce invisible radiation that may be harmful to human 
eyes.   Never look directly into the optical port of any fiber optic 
unit designed to operate with single-mode optical fiber. 

 

NOT FOR LIFE SUPPORT SYSTEMS 

Liteway, Inc. does not authorize or warrant any of its products or 
accessories for use in critical life support systems or applications 
of any kind. 

 

 
 
© Copyright 2017 Liteway, Inc.              

 

 

 

108515  Rev E 

OPERATING INSTRUCTIONS 

 
 

Redundant Signal  

Switch 

Model RSW-1002 

 
 
 
 
 

 
 
 
The RSW-1002 is a two input single output automatic switch 
designed to implement a redundant, fail-safe signal transmission  

Technical Specifications 

Video Bandwidth 

DC to 100 MHz 

In/Out Impedance 

75 ohms 

In/Out Signal Level 

3 volt peak to peak 

Signal/Noise Ratio 

75 dB/min 

Differential Gain 

0.5% max 

Differential Phase 

0.3º max 

Field Tilt 

1% max 

Indicator Lights 

Pwr, Input 1, Input 2, Fault, Alarm 

Signal  Connectors 

BNC 

Temperature Range 

-35º to +75ºC 

Power Requirements 

11-24 VAC/DC @150 mA 

Physical Size (mm) 

 5.0”(127)L x 1.0” (25.4)W x 3.0”(7)D 

All specifications are subject to change without prior notice. 

 
 

!