LiteGear Xona Maxima Basic Installation Manual Download Page 4

4   Xona Maxima Anleitung / manual

Installation und Montage

 

Installation

PE

Erdung / Ground

EL1

Notversorgung 1 / 

Emergency 1 Supply Live

EN1

Notstrom N1 / 

Emergency 1 supply Neutral

 

EL2

Notstrom L2 / 

Emergency 2 supply Live

EN2

Notstrom N2 / 

Emergency 2 supply Neutral

 

L1/L2/L3

stromführende Phase, entsprechender Neutralleiter ist N1 / 

live wire, corresponding neutral wire is N1

L4/L5/L6

alternative stromführende Phasen, entsprechender Neutralleiter 
N2 / 

another group of live wires, corresponding neutral wire N2

DIM+

1-10V+

DIM-

1-10V-

DA/L

DALI+ / 

Push Dim L

DA/N

DALI- / 

Push Dim N

CHR

Ladeeingang für interne Batterie, Hauptversorgungserkennung / 

Charge input for internal battery, main supply detection

 
 
 

Funktionsbeschreibung

Function Description

Kabelbezeichnung

Description of the wires

Mode

3 phase

DALI

1-10V

Batt

EMG1

EMG2

1

2

3

4

5

6

7

8

9

10

11

12

5-adrige Tragschiene:

5-core trunking rail

1

L1

N

L2

PE

L3

8-adrige Tragschiene:

8-core trunking rail

2

CHR

L1

N

L2

PE

L3

DIM+

DIM-

3

CHR

L1

N

L2

PE

L3

DA/L

DA/N

4

CHR

L1

N

L2

PE

L3

EL1

EN1

12-adrige Tragschiene:

12-core trunking rail

5

CHR

L1

EL1

N

EN1

L2

EN2

PE

EL2

L3

DIM+

DIM-

6

CHR

L1

EL1

N

EN1

L2

EN2

PE

EL2

L3

DA/L

DA/N

7

x2

CHR

L1

L4

N1

N2

L2

L5

PE

L6

L3

DIM+

DIM-

8

x2

CHR

L1

L4

N1

N2

L2

L5

PE

L6

L3

DA/L

DA/N

!

Bitte beachten Sie, dass nur die fünf Hauptkabel L1,L2,L3,N und PE in 2,5mm² (16A) 
Querschnitt ausgeführt sind! Alle anderen Kabel haben einen Querschnitt von 1,5mm² 

 

Note Only L1,L2,L3,N1 and PE wires are 2,5mm² with 16A, the rest are 1,5mm² with 10A:

Summary of Contents for Xona Maxima Basic

Page 1: ...Xona Maxima Anleitung manual 1 CRI 80 IP30 5 YEARS Guarantee PF 0 95 IK02 20 C BIS 50 C LED Lichtlinien System LED linear light system Montageanleitung Installation manual Xona Maxima Basic...

Page 2: ...lectric shock falling parts cuts abrasions and other hazards please read the following notes before mounting this device Read the instructions before mounting installation and hand it over to the cust...

Page 3: ...ode T Verbinder T node Sensor Modul mit Verriegelung und phasen ber griff 599 1499mm sensor module 599 1499mm Blindabdeckung 599 1499mm Stahl oder Kunststoff blankcover 599 1499mm steel or PC Leuchten...

Page 4: ...internal battery main supply detection Funktionsbeschreibung Function Description Kabelbezeichnung Description of the wires Mode 3 phase DALI 1 10V Batt EMG1 EMG2 1 2 3 4 5 6 7 8 9 10 11 12 5 adrigeTr...

Page 5: ...nual 5 Installation und Montage Installation L1 N L2 PE L3 12 adrig 12 cores EN2 L5 EL1 L4 EN1 N2 L2 EL2 L6 PE L3 DIM DA N L1 L2 CHR N N1 PE DIM DA L CH L1 N L2 PE L3 DIM DA L EL1 DIM DA N EL1 5 adrig...

Page 6: ...ieren Sie die Endkappe um die Leuchte von beide Seiten zu schlie en Position the end cap to close the luminaire from both sides F hren Sie das Kabel mittels einer Kabeleinf hrung ein pass the ca ble d...

Page 7: ...ax 100 800mm max Leuchtentr ger mit Stromschienen montieren mounting cover with rail out for tracklight Blindabdeckung montieren mounting blankcover Bitte beachten Sie Der erste Aufh ngepunkt am Anfan...

Page 8: ...hts on one phase Installation und Montage Installation 35W 35W DALI 50W 70W Leitungsschutzschalter Circuit breaker B16A 13 Unit 21 Unit 8 Unit 5 Unit Leitungsschutzschalter Circuit breaker C10A 12 Uni...

Reviews: