Litecraft SUNX.10 User Manual Download Page 2

14

•  Each person which is responsible for the installation, the use 

or service of this unit must be:

 

• qualified

 

• has to follow the instructions in this manual.

WARNING!
Be careful when using the device. You risk an electrical shock 
from high voltage, if you touch the wires!

•  The device has left our company in manufacturer proofed 

state. To maintain this status and to ensure a permanent 
safe operation, it is absolutely necessary to follow the safety 
instructions and warnings in this manual.

IMPORTANT!
Errors, caused by not following these instructions are not cov-
ered by the warranty. The manufacturer will not accept liability 
for any resulting defects or problems.

•  Keep the unit away from radiators or other heat sources!
•  If the unit has been exposed to tremendous temperature 

changes (e.g. after transportation), do not turn it on imme-
diately. The resulting condensation could damage the unit. 
Don`t switch unit on until the device reaches room tempera-
ture. 

•  This device belongs to protection class I. Therefore, it is im-

perative that the green/yellow wire is connected to the earth 
contact of the plug. The electrical connection must be made 
by a qualified person. 

•  Make sure that the cable has never been squeezed or dam-

aged by sharp objects. Check the device and the cables regu-
larly. 

•  If the cable is damaged, it must be replaced immediately by 

the manufacturer, its service agent or a qualified person in 
order to avoid danger.

•  Lenses, glasses or UV filters must be replaced if they are 

visually damaged, or their effectiveness is impaired, e.g. by 
broken glass or by deep scratches.

•  Ensure that wires never come in contact with other wires! 

Handle the power cord and all connections with caution!

•  Make sure that the line voltage is not higher than the voltage 

specified in this manual. 

•  Disconnect the unit from the AC mains when it is not in use or 

when cleaning it. Disconnect the connection only by pulling 
the cable plug.

•  Using the fixture for the first time, can result in light smoke 

and odors. This is a normal process and does not constitute a 
defect. 

RISK OF BURNS! 
Do not touch the unit during operation! The housing may reach 
high temperatures. 

RISK TO HEALTH! 
Never look directly into the light source. Especially epileptics 
risk an epileptic shock! Disconnect the unit from the AC mains 
when not in use or when cleaning it.

•  Defects caused by modifications of the device by unqualified 

handling or an unqualified person are not covered by the 
warranty. 

•  Keep the product away from children and unskilled people.
•  There are no wear parts in the device. Maintenance and ser-

vice must be performed only by an authorized service partner.

This product is a spotlight, which is designed only for profes-
sional use on stages, discotheques, theatres, etc. This product is 
approved for mains connection up to 240 VAC and designed for 
indoor use.

•  Please avoid any kind of shocks and outer actions during its 

installation or transportation.

•  Take care of too high ambient temperature, humidity and 

dust when choosing the installation location. Assure that all 
cables are fixed. Incorrect operation may lead to danger.

•  Image  

  shows the minimum distance to illuminated 

objects. Minimum distance between fixture and illuminated 
surface is 0,5 meters 

•  Assure that the area below the mounting position of the 

fixture is roped in while mounting, dismantling and service.

•  The spotlight itself and its accessories like color frame and 

barndoors have to be safed with a suitable safety chain.

•  Assure that the maximum ambient temperature is never 

exceeded. 

•  Do not put the fixture in operation before you are familiar 

with its functions. Keep the product away from children and 
unskilled people.

  Safety Notes

  Designated Use

Summary of Contents for SUNX.10

Page 1: ...Bedienungsanleitung User Manual...

Page 2: ...he voltage specified in this manual Disconnect the unit from the AC mains when it is not in use or when cleaning it Disconnect the connection only by pulling the cable plug Using the fixture for the f...

Page 3: ...and the fixture itself Never try to do the installation by yourself if you are not qualified instead you have to instruct a skilled installer Inappropriate installa tions can cause injuries and or dam...

Page 4: ...mains is only allowed by skilled persons Before connecting the fixture to the mains assure that the specifications are corresponding Electrical grounding has to be used in the whole installation ATTEN...

Page 5: ...ew Mains Input Mains Output 1 2 3 4 5 6 7 5 6 7 8 1 9 10 11 12 13 2 3 4 8 9 10 11 12 13 Enter Button Down Button DMX Input 3 pin DMX Output 3 pin DMX Input 5 pin DMX Output 5 pin DMX OU T DMX IN DMX O...

Page 6: ...rs by menu M S Mode Speed 0 100 setting speed in 100 steps for the pre programmed chaser available default setting Show Speed 100 Static Dimmer Dimmer 0 255 setting brightness in steps of 256 Strobe 0...

Page 7: ...3 15 Ch 001 498 default setting 1 DMX Channel Channel 5 Ch 10 Ch 15 Ch setting DMX channel mode description of modes in next chart default setting 5 Ch Master Slave Master Slave Master Slave setting w...

Page 8: ...5 steppless speed s f ch5 dimmer mode 000 051 mode set on display 052 101 dimmer mode linear 102 152 dimmer mode 1 153 203 dimmer mode 2 203 255 dimmer mode 3 10 channel mode Channel 10 Ch ch1 dimmer...

Page 9: ...h9 dimmer LED 9 000 255 stepless brightness ch10 dimmer LED 10 000 255 stepless brightness ch11 programms 000 010 no function 011 038 programm auto 1 039 066 programm auto 2 067 094 programm auto 3 09...

Page 10: ...x 1 875 lx 675 lx 345 lx 169 lx 10 color 1 m 3 m 5 m 7 m 10 m white 57 725 lx 6 414 lx 2 309 lx 1 178 lx 578 lx beam spread chart beam spread chart distance m distance m diameter diameter 25 10 0 0 1...

Page 11: ...Technical Specification kg mm voltage 100 240 V 50 60 Hz power consumption 0 5 A 230 V measurements 99 2 x 6 9 x 19 6 cm DMX channels 5 10 15 weight 4 9 kg fuse T2 A 250 V ip rating IP 20...

Reviews: