background image

ISO 9001 CERTIFIED

www.liteputer.com.tw

Lite-Puter

DX-610/626 [EUM-

]

7

(Dimming)

(Switching)

2 - 4

Warm Up Setting (0…6%)

STEP-1 press

FNC

key .

STEP-2 press

FNC

key to select the setting channel, EX :select channel 1

STEP-3 press

,

key to adjust.

2 - 5

Channel Output Status Preview

STEP-1 Enter to DMX status and press

DMX

key.

STEP-2 press

or

to preview.

2 - 6

Manual Dimming

STEP-1 Push

VR1-VR6

to do the prompt dimming output of individual channel.

When there is another signal inputting from a console, it will take the higher value as

the output.

2 - 7

Display The Dimming Value of DMX Channel,Internal Temperature.

Press

L

to display the dimming value of DMX channel.

Press

T

to display the internal temperature.

Channel 1 set on 6% for warm up.

Summary of Contents for DX-610

Page 1: ...O 9001 CERTIFIED www liteputer com tw Lite Puter DX 610 626 EUM I 1 DX 610 DX 626 6CH DMX DIMMER PACK User Manual Lite Puter Enterprise Co Ltd Website www liteputer com tw E mail sales liteputer com t...

Page 2: ...3 1 3 Specification 3 1 4 Front panel 4 1 5 Output terminal board Sockets panel 4 1 6 Wiring diagram 5 Chapter 2 Operation 6 2 1 Standard DMX512 Signal 6 2 2 DMX start address setting 6 2 3 Dimming Sw...

Page 3: ...esting DO Not over 30 minutes 3 DX 610 the output of each channel is 8A For several hours use Theaters Stages DX 626 the output of each channel is 16A For several hours use Theaters Stages 4 DX 610 th...

Page 4: ...10 10A no fuse breaker DX 626 25A no fuse breaker Fan for temperature controlling to sink heat and clean the dust inside 37CFM X 1 The front panel can be dismantled easily for quick repair 1 3 Specifi...

Page 5: ...hone jack 7 No fuse breaker Channel 1 3 4 LED display function keys 8 No fuse breaker Channel 4 6 1 5 Output Terminal Board Sockets Panel TERMINALTYPE 9 10 11 12 13 9 DMX connector RJ11 phone jack 12...

Page 6: ...ch channel DX 626 15A each channel external power no fuse breaker is necessary when mounting SCHUKO TYPE Output sockets DX 610 10A each channel DX 626 16A each channel external power no fuse breaker i...

Page 7: ...EP 1 press DMX key into DMX status STEP 2 press and hold the FNC key for 3 sec STEP 3 press FNC key to select channel STEP 4 press or to select dimming mode or switching mode DX 626 is a 6 channel dim...

Page 8: ...iew STEP 1 Enter to DMX status and press DMX key STEP 2 press or to preview 2 6 Manual Dimming STEP 1 Push VR1 VR6 to do the prompt dimming output of individual channel When there is another signal in...

Page 9: ...f unit the DMX will activate to DMX status 2 9 Protocol Control When the protocol control turn on it only receive the DMX signal whose break width range from 88us to 230us STEP 1 Press FNC and LED dis...

Page 10: ...r free within a year since the distributing date 3 We do not offer door visiting service If the trouble appears in Lite Puter s products please deliver the equipment to local distributors or Taipei he...

Page 11: ...w liteputer com tw E mail sales liteputer com tw Shanghai Factory Lite Puter Technology Shanghai Co Ltd Address Building B5 No 298 Lane 3509 Hongmei S Road Shanghai China Zip Code 201108 Tel 86 21 544...

Reviews: