background image

 

DP-DL01D [EUM-E]                                                                                                                                              18 

3.9 EDX to DALI Patch 

The “EDX to DALI Patch” function is to make EDX commands able to control DALI devices. 

You can use EDX scene control panel (ECP-110T, ECP-310) to recall the scenes of DALI ballasts. 

By doing this, a DALI system can be integrated to EDX system. 

 

Please refer “EDX to DALI System Diagram”. 

 

1. Click “EDX to DALI” tab 

 

 

2. You can patch/map DALI address to EDX zone/channel. Click “Save” to store the change. 

 

 

EX: DALI address 05 is patched to EDX zone1/channel 1: 

EDX’s zone1/ channel 1 command will control DALI address 05. 

EDX’s zone1 scene command will trigger the corresponding scene in DALI devices whose address is 05. 

 

Summary of Contents for DP-DL01D

Page 1: ...DP DL01D EUM E 1 User Manual DP DL01D EDX DMX to DALI Interface...

Page 2: ...TION 8 2 1 ID SET 8 3 EDX TO DALI GUI 9 3 1 INSTALL EDX TO DALI 9 3 2 CONNECT TO EDX TO ETHERNET INTERFACE 9 3 2 1 Connect by Using USB Cable Only Applicable to DP 107E 11 3 3 ID NUMBER OF DP DL01D 12...

Page 3: ...1 Features 1 Convert EDX signal to DALI signal 2 Convert DMX 512 to DALI 3 Control up to 64 DALI ballasts drivers 1 2 Specifications 1 Power Input AC 100 240V 2 Protocol DALI EDX DMX 512 3 Dimension...

Page 4: ...40V Input 5 ID Number Switch 6 EDX DMX 512 port 7 DALI port 1 4 About EDX DMX 512 Wiring The digital signal wiring is basically the same as RS 485 wiring If you are not familiar with RS 485 wiring ple...

Page 5: ...DP DL01D EUM E 5 1 5 System Diagram 1 5 1 EDX to DALI System By Ethernet DP 107E or DP 104...

Page 6: ...DP DL01D EUM E 6 By USB Only Applicable For DP 107E...

Page 7: ...DP DL01D EUM E 7 1 5 2 DMX 512 to DALI System...

Page 8: ...ID Set ID number can be configured by DIP switch The number configuration is based on BCD code Each switch on the 10 digit DIP switch represents as following figure Examples ID number is 01 1 ID numbe...

Page 9: ...P DL01D Please refer the previous EDX to DALI wiring diagram 3 1 Install EDX to DALI Install EDX to DALI application in Windows 3 2 Connect to EDX to Ethernet Interface Run the application and enter t...

Page 10: ...DP DL01D EUM E 10 Click Select button in the interface list to connect to the network interface...

Page 11: ...ct by Using USB Cable Only Applicable to DP 107E It is also possible to use USB port of DP 107E to configure DP DL01D Simply connect DP 107E s USB to the PC and run EDX2DALI GUI Click Connect in Confi...

Page 12: ...k DALI Setting tab 2 Click Search If some DALI ballasts are previously addressed and some DALI ballasts are not addressed yet please check Expansion and then click Search The newly installed ballasts...

Page 13: ...re randomly addressed during search process You can use Change DALI Address function in DALI Setting tab to change the address after searching process 3 4 Change DALI Address In DALI Setting tab find...

Page 14: ...ams tab 2 DALI parameters can be read write Max Level the maximum output level Min Level the minimum output level Power On Level the output level when power is supplied System Failure Level the output...

Page 15: ...utput level to requested output level Please refer the table below for real fade time n Fade Time 1 0 707 s 2 1 000 s 3 1 414 s 4 2 000 s 5 2 828 s 6 4 000 s 7 5 657 s 8 8 000 s 9 11 314 s 10 16 000 s...

Page 16: ...cenes 1 Click DALI Scene Setting tab 2 You can read set DALI scenes by DALI address 3 If you want to check the real time output please check Real Time Output The DALI output level will be controlled b...

Page 17: ...DP DL01D EUM E 17 3 8 DALI Command Test 1 Click DALI Command tab 2 You can set DALI dimming level or recall DALI scenes...

Page 18: ...doing this a DALI system can be integrated to EDX system Please refer EDX to DALI System Diagram 1 Click EDX to DALI tab 2 You can patch map DALI address to EDX zone channel Click Save to store the c...

Page 19: ...19 EX DALI address 01 is patched to EDX zone 2 channel 3 EDX s zone2 channel3 command will control DALI address 01 EDX s zone2 scene command will trigger the corresponding scene in DALI devices whose...

Page 20: ...le to control DALI devices Please refer DMX 512 to DALI System Diagram 1 Click DMX 512 to DALI tab 2 Set corresponding DMX 512 to DALI address mapping and click Save to store the change If DALI addres...

Page 21: ...ontrol c Labor costs incurred in diagnosis of defects installation reinstallation wiring rewiring repairing adjustment or reprogramming of a product or any other consequential expenses d Other Lite Pu...

Reviews: