background image

 

Operation Manual 

 

 

Masonry Saw  

 

DTS 120 and DTS 120 - G 

 

 

 

Make this operation manual accessible to your operation staff in order to 

ensure that the machine will always be utilised correctly and remains in easy 

to handle condition! 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maschinenbau GmbH 

Lanzstraße 4 - D-88410 Bad Wurzach 

T49 (0) 75 64/3 07-0 - Fax + 49 (0) 75 64/3 07-5 00 

[email protected]  -  www.lissmac.com 

 

State: 10/2009 

Translation of the original operating manual 

Summary of Contents for DTS 120

Page 1: ...aff in order to ensure that the machine will always be utilised correctly and remains in easy to handle condition Maschinenbau GmbH Lanzstra e 4 D 88410 Bad Wurzach Telefon 49 0 75 64 3 07 0 Fax 49 0...

Page 2: ...and place of operation It must be read thoroughly and be applied by each person charged with performing works using this machine such as Operations including set up routines trouble shooting during op...

Page 3: ...red part of the intended use 1 2 2 Only use and operate this machine in perfect technical condition as well as in accordance with regulations and be always aware of safety requirements and dangers and...

Page 4: ...ever without the supplier s previous consent Danger 1 3 10 Only use original spare parts from the producer Danger 1 3 11 Thoroughly observe servicing terms as prescribed or indicated in this operation...

Page 5: ...e re placed the case given be checked by a specialist Operative condition of the protective devices Sufficient cooling water supply dry cuts prohibited Danger 1 5 1 8 Do not tilt the saw blade Danger...

Page 6: ...t for the prescribed current intensity rate only Switch off machine immediately in case troubles with the electric power supply to the machine occur Danger 1 6 1 2 Only perform maintenance and repair...

Page 7: ...ut adjustment 2 2 Protective devices Pos 4 Blade guard Pos 9 Splash guard 2 3 Technical data DTS 120 DTS 120 G Operation voltage Motor output 230V 2 2 kW S6 40 230V Number of revolutions 2800 r p m Sa...

Page 8: ...8 8 10 11 1 12 6 4 7 2 9...

Page 9: ...9 3 5 13 2 9 4...

Page 10: ...ath Put the sawing table on 3 3 Fitting of the saw blade or control of fitting Note The stop plate of the saw head height adjustment Pos 6 is prepared for a saw blade with 350 mm diameter Remove cap n...

Page 11: ...er Take the saw table off Danger Dislocation via building crane prohibited 4 2 Two persons needed for carrying the saw Danger Take the saw table off 5 Operation 5 1 Placing of the saw Place the saw on...

Page 12: ...S 120 G Attention You can only adjust a mitre joint of 45 and 90 The saw table will get damaged for all other degrees Loosen the screws Pos 13 Turn the saw head to 45 or 90 Tighten the screws Pos 13 6...

Page 13: ...le cutting operation continuous can neverheless be re started after a short break time Advance too high Saw blade is blunt Saw blade worn coating 2 mm Cut with lower advance Regrind saw blade by cutti...

Page 14: ...utches and switches for pneumatic hydraulic water elektricity fuel guidance elements as guiding joints guiding bushes guiding rails rolls bearing antislipping devices flushing head seal sliding and ro...

Page 15: ...Measured sound power level 88 dB Guaranteed sound power level 89 dB Applied standards and regulations EC Machine guidline 2006 42 EG Sound emission 2000 14 EG Low voltage directive 2006 95 EG Electro...

Page 16: ...16...

Reviews: