background image

 

 

 

            

 

   DIREZIONE 

    Via Veneto, 8 

– I-24041 Brembate (BG)   

    Tel. +39 035 4826195 

– Fax +39 035 2283818 

 
    

www.liski.it

  - [email protected] 

 

 

 

3

 

 
 
 
 

4)

 

INSTALLATION 

 
To  put  the  poles  into  the  snow,  ice  or  ground,  LISKI  suggest  to  use  a  Ø  32  or  35  mm  drill  bit, 
depending on the snow conditions.  
 
Assemble the protection system putting the net into the 2 pole hooks; the hooks should be all at the 
same height (1 at top, 1 at low of the pole), the lower hook should be forward down, the other one 
forward up. 
 
The groups of net, all of the same kind, should be attached and the “uphill” group should surmount 
the “downhill” group, to avoid that the fallen skier can impact and pass through the only opening of 
the  net,  at  the joint  by  two net groups;  do not  align joints  of net  sections in  the same  direction of 
impact of the skier. 
 
The number of  rows that  must  be  placed depending by  situation and  by  danger level,  LISKI  BC-130 
NET can be placed in 1,2,3 or more rows; install the second row of net parallel to the first net, the 
distance between the two nets should be as described in the set-up model. 
 
 

 EXAMPLE OF “LISKI” BC-130 NET  PROTECTION SYSTEM  

SET-UP MODEL  

 

 

 

 
 
 
 

 
 
IMPACT DIRECTION 
The “Uphill” group (red) should surmount at the “Downhill” one 
(blue) to avoid that the fallen skier can impact and pass through 
the only opening of the net, at the joint by two net groups.  
 
 
 