INS LISA 1DR.vsd Created: 10-6-201 7 Revise d:10-6-201 7
Pag e 3
P1 & P2 = 1",
P0 = ¾
Door
Top edge of the door
Frame
1-1/8"
Not
ched
edg
e of
the
H
inge
Fig-1
Fig-2
Fig-1
Fig-2
Fig-3
Fig-3
Pilot Hole
Fig-4
Fig-4
Sensor Mounting Plate
First Mounting Hole
Door
Door
Self
–
Tapping / Wood
Screws
Sensor Mounting Plate
Fig-5
Fig-5
Wiring Hole
3/8"-
7/16"
Door
Loc
k
Ed
ge
of
the
Door
Fig-5
Slot Provided
Door
Cover screw
Sensor Cover
Fig-6
Fig-6
1) Mark a horizontal line 1" from the top of the door for models P1 & P2,
¾
for P0, and extend to the lock edge of the door as shown in .
2) Mark a vertical line 1-1/8" from the notched edge of the hinge as
shown in .
3) Mark center point at horizontal and vertical line intersects. Drill
pilot hole of 1/8" as shown in .
4) Loosen sensor cover screws enough to enable removal of the sensor cover form the mounting plate.
Loosen sensor adjustment nuts.
5) Place sensor mounting plate on the door with first mounting hole over pilot hole as shown in . Pull
out wire from wiring hole.
6) Temporarily secure the hinge side sensor mounting plate on door with two self-tapping / wood screws as
shown
in .
7) Loosen adjustment nuts on mounting plate and Slide the sensor mounting plate towards the lock edge of
the door so that there is no more than 3/8"-7/16" gap between the sensor mounting plate & the lock edge as
shown in .
8) Line up the cover screws of the sensor cover with
the slots provided on the sensor mounting plate. Adjust the sensor cover as needed. Attach sensor cover
to the mounting plate and
loosely
tighten the cover screw provided as shown . Sensor cover
must extend over the top of the door, but make sure the top of the cover extends no more than
above the top of the door. Test the operation of the sensor.
PULL SIDE OF THE DOOR
Telescoping Sensor
PULL SIDE OF THE DOOR
Telescoping Sensor
DOOR SENSOR
Please Read Completely Before Starting
Door Sensor