Liquip Sales GPI EZ-8 Owner'S Manual Download Page 5

921803-01 Rev F

5

Step  5 

 

If the power cord provided is too long, using a util-
ity knife, cut to desired length. Using utility knife, 
carefully strip 3 to 4 inches (7.5 to 10 cm) of outer 
insulation from end of power cord. 

DO NOT CUT 

INNER WIRES

. Next, strip ¼ inch (0.6 cm) of insu-

lation from the black and red power cord wires.

Step  6 

 

For a negative ground system, first disconnect the 
vehicle’s ground wire, and then wire as follows: 
Insert one end of the fuse (J) into the wire con-
nector (H) and crimp. Insert the red power cord 
wire into the other end of the wire connector and 
crimp. Make sure the fuse is positioned outside 
of hazardous areas and as close to the battery 
as possible. Make a solid electrical connection to 
the grounded side of the battery with the remain-
ing black wire. Connecting directly to the battery 
terminal or the end of the battery cable is recom-
mended.

Step  7 

 

For temporary wiring: Connect the red and black 
power cords to alligator clamps (not included) 
(Figure 6).

Figure 6

Step  8 

 

For permanent wiring: 
Connect the red and black power cords to termi-
nal post rings (not included) (Figure 7).

Figure 7

Step  9 

 

Check all connections to make sure they are con-
nected per instructions and all electrical codes. 
The installation is now complete.

Step  4 

 

Place the nozzle into the nozzle holder on the end 
of the pump motor housing. Note that the nozzle 
cannot be placed in the holder unless the pump 
switch is OFF (Figure 5).

Figure 5

CONNECT TO A POWER SOURCE

Please consult the Owner’s Manual for your vehicle 
before proceeding.

NOTE:

 The pump is designed for use with a 12-

volt power source. Do not attempt installation 
on a 24-volt or 115-volt system.

WARNING: 

Do not attempt to power the pump 

from vehicle wiring smaller than 14 gauge, 
such as the cigarette lighter wire, as these thin 
wires could overheat and cause a fire.

NOTE:

 This pump is pre-wired for installation in 

CLASS I, DIVISION 2 locations such as portable 
fuel tanks, trailers, etc. Connection to a battery 
will depend upon the application.

WARNING: 

If pump is to be installed in 

a CLASS I, DIVISION I location please 
contact GPI for the appropriate product.

Verify switch is in OFF position, then route the 
electrical wires to the source of the vehicle power 
system. Be sure to support the wires as neces-
sary and protect them from sharp edges, heat or 
anything that could damage the wires.

Summary of Contents for GPI EZ-8

Page 1: ...t possible service life it is important that you follow the operation and maintenance procedures outlined in this manual We are proud to provide you with a quality product and dedicated support Our co...

Page 2: ...and disposal GENERAL INFORMATION The purpose of this manual is to assist you in in stalling operating and maintaining your GPI EZ 8 or EZ 8 Methanol 12 volt DC pump with manual nozzle NOTE This pump i...

Page 3: ...s be prepared with your original sales slip or other evidence of purchase date Please contact GPI before returning any parts GPI can inform you of special requirements you will need to follow CAUTION...

Page 4: ...hose into the 90 street elbow and tighten securely Thread opposite end of hose into nozzle F and tighten securely Figure 4 Figure 4 INSTALLATION INSTALL PUMP ON TANK Step 1 NOTE For EZ 8 with Spin Co...

Page 5: ...rings not included Figure 7 Figure 7 Step 9 Check all connections to make sure they are con nected per instructions and all electrical codes The installation is now complete Step 4 Place the nozzle in...

Page 6: ...s Tighten loose tank lids regularly To Dispense Fuel Turn on the pump by removing the nozzle from the holder and pushing up the switch lever Insert the nozzle into the receiving tank and squeeze the h...

Page 7: ...Connect red wire to positive ungrounded side of battery Correct Rotatio n Figure 14 Strainer Figure 10 Suction pipe clogged damaged or missing Remove pump from tank Inspect suction pipe Clean or repla...

Page 8: ...0 lbs 7 5 kg with manual nozzle LOW FLOWRATE Fuel tank empty Fill tank Strainer partially clogged Inspect and clean as required Suction pipe clogged or damaged Remove pump from tank Inspect suction pi...

Page 9: ...er 1 Kits and Accessories Item No Part No Description 110037 1 Bushing Tank Bung Adapter Spin Collar Model 13750006 Drive Key Kit includes Drive Key 13750001 Fuse Holder Kit includes Fuse Holder Fuse...

Page 10: ...921803 01 Rev F 10...

Page 11: ...921803 01 Rev F 11...

Page 12: ...ct and to any person to whom such product is transferred during the warranty period This warranty shall not apply if A the product has been altered or modified outside the warrantor s duly appointed r...

Reviews: