Rev: 10.16.20

Page 2

CCD-0003782

PROJECT 2000

®

 TOPLINE BEDLIFTING PLUS 

PROGRAMMING STOP POSITIONS (EU)

TI-360

POWER AND MOTION

2. 

A hidden (NULL) button (Fig. 1C) is located between the UP and DOWN buttons to initiate the stop 

position program and to set the stop positions. To initiate the stop position program use steps A-C.

Note: 

The buttons must be pressed slowly, keeping approximately a one second gap between presses.

A. 

Press and hold the NULL button while pressing the UP button (Fig. 1B) twice, then press the 

DOWN button (Fig. 1D) twice, then finally press the UP button once.

B. 

The green light with the wrench icon (Fig. 1E) should turn on.

C. 

If the green light (Fig. 1E) does not turn on, release the hidden NULL button and repeat step A.

3. 

If the memory was empty, the red warning light (Fig. 1F) will keep flashing. Before continuing with the 

following operations, it is necessary to reach the end-of-stroke position. The controller does not allow 

storage of any data until the end-of-stroke position is detected. To program stop positions: 

the controller does not allow storage of any data until the end-of-stroke position is detected.

the end-of-stroke position MUSt be set before operating the system.

Fig. 1 

A

A

e

F

B

D

C

4. 

Press and hold the UP switch (Fig. 1B) to reach the bed's end-of-stroke position.

Note: 

The bed will automatically stop: 

Do Not

 release the UP switch until the bed has stopped. If the red 

warning light (Fig. 1F) was flashing, it will turn off when the end-of-stroke position is reached.

5. 

Starting from the end-of-stroke position, set the other stop positions. Press the DOWN button (Fig. 1D) 

until the desired position is reached.

6. 

To store this stop position, press and hold the hidden (NULL) button, then press the DOWN button at 

the same time. The green lights indicating the bed direction (Fig. 1A) will both turn off, communicating 

the data was stored.