Determining the Mounting Position and Installing Leveling Sensors
Mounting Position of Leveling Sensors
The leveling sensors have a limited
mounting area for proper performance. The
front sensor must be within 36” from the
front of the frame as signified by Section
A in (Fig.11). Ensure that the front sensor
is mounted in front of the front leveling
jacks. The rear sensor must be in line with or
behind the rear leveling jacks, as signified
by Section B in (Fig.11 and Fig. 12). Both the
front sensor and the rear sensor must also be
mounted in line with the center of the frame,
as signified by the dotted blue centerline in
(Fig.11 and Fig. 12).
Fig. 11
Rear of Trailer
Front of Trailer
Section A
Section B
Front Left
C-Jack
Rear Left
C-Jack
Front Right
C-Jack
Rear Right
C-Jack
Centerline
Fig. 12
Rear of Trailer
Section B
Rear Left
5K Jack
Rear Right
5K Jack
Centerline