LionTec GmbH – Gewerbepark Birkenhain21 – D-63579 Freigericht – Germany – +49 6051 916679-0– www.liontec.eu – [email protected]
4. Cooling
The Mobile Power Systems has an intelligent cooling system which turns on under the following
conditions:
Inverter load > 400W
2. 5V USB load > 10W
Type C-PD load > 30W;
12V cigarette lighter load > 50W
PV input power > 100W.
Beside this functions, the intelligent cooling system will adjust the PV input or AC output power
based on the outer case temperature. Therefor keep the outer case at a touchable temperature.
4. Maintenance
There is no maintenance necessary.
5. Care
The Mobile Power Supply must be kept clean. If cleaning is required this must be carried out by
dry cloth only.
6. Storage
Keep the storage temperature within normal range as 0° C to 30° C. Do not store the Mobile
Power Supply in direct sunlight.
7. Troubleshooting
Fault code
Cause
Action
E001
All battery over-voltage protection
No charge, only discharge.
E002
All battery low-voltage protection
Fully charged and re-power on
E003
All battery failure
Re-power on generator and charge
E004
All battery discharge
overtemperature protection
Temperature is too high. Repower on after cool down.
E005
All battery discharge
lowtemperature protection
Environment temperature is too low. Repower on when
environment temperature is higher.
E006
All battery charge
overtemperature protection
Battery pack is over-temperature. Charge when the
temperature is lower.
E007
All battery charge lowtemperature
protection
Battery pack is low-temperature. Charge when the
temperature is higher.
E008
1st group battery low-voltage
protection
Charge and repower on
E009
2nd group battery low-voltage
protection
Charge and repower on
E010
3rd group battery low-voltage
protection
Charge and repower on