10
If the PowerMaster is assigned an ENG ID#:
1. Assign a unique
ENG
ID#. Refer to page 10.
2. Press
ENG
on the CAB-2 Remote.
3. Enter the ID# assigned to the PowerMaster.
4. Press
INFO
.
5. Enter a name and road number for the PowerMaster if desired. Refer to the Legacy Control
System manual for more information.
6. Press
SCROLL
to display the Type screen.
7. Select the device type
• For LEGACY System with Version 1.4 update select XFMR.
• For LEGACY System with Version 1.3 or lower select DSL.
8. Press SCROLL again to display the Control screen.
9. Select the control mode.
• For LEGACY System with Version 1.4 update select CAB-1, TMCC or LEGACY.
• For LEGACY System with Version 1.3 or lower select CAB-1.
Using TMCC or LEG control modes with LEGACY system Version 1.3 or lower will
result in unexpected operation.
10. Press
CTC
to exit.
Note!
Setting the device type and control mode for the PowerMaster with a
CAB-2 Remote Control
I
f the PowerMaster has been assigned an ENG ID# you will need to select a device type and
control mode for the output so the CAB-2 Remote Controller knows how to operate the
controller. You may also give the PowerMaster a name and a road number. If the PowerMaster
has been assigned a TR ID# you will only need to set the control type.
If the PowerMaster is assigned an TR ID#:
1. Assign a unique
TR
ID#. Refer to page 11.
2. Press
TR
on the CAB-2 Remote Control.
3. Enter the ID#.
4. Press
INFO
.
5. Press
CLR
. Display will ask NAME & ENGINES?
6. Press
YES
.
6. Press
CTC
to exit.
Summary of Contents for Legacy PowerMaster 360W
Page 22: ...22 Notes ...