Misty Electronic Blindmask 

User’s Manual 

Version 1.2 | 19/04/19 

 

Page 11 

 

 

More than two Misty Student Units 

It is possible to train students in the same space and to work with more than one Misty set at the same 
time. To do so, each set is adjusted to a different group. It is also possible to work with more than two 
Student Units in combination with a single Instructor Unit. The example given below illustrates the 
various options available. 
 
 
 
 
 
 
 

Simultaneous training with several Misty sets 

The instructor can divide the group in two, work with two Misty sets adjusted to two different groups, and 
use two Instructor Units to train the students. 
However, in this case, the instructor must operate two Instructor Units at the same time.  
 

Simultaneous training with a single Instructor Unit 

The Misty set also provides the option of working with more than two Student Units in combination with  a 
single Instructor Unit. To do so, simply set all the Student Units to the desired group channel, and divide 
them proportionately between the setting Student A and Student B. 
The above example would then result in the following configuration: 
 

Instructor Unit: 

 

Set to group 1 

Student Unit 1: 

 

Set to group 1, unit A 

Student Unit 2: 

 

Set to group 1, unit A 

Student Unit 3: 

 

Set to group 1, unit B 

Student Unit 4: 

 

Set to group 1, unit B 

 
All four Student Units will now work on group setting 1 with the same Instructor Unit. However, as more 
than one unit is set to the A and/or B setting at the same time, it will be more difficult to determine which 
Student Unit is generating an alarm or which Student Unit has a low battery. The Instructor Unit was 
initially developed to work with two Student Units and therefore offers only two options, A or B, to identify 
the source of an alarm. 
 

Training separately with a single Instructor Unit 

It is also possible to divide the 4 students into groups of 2. The first group can s tart training with the 
Instructor Unit set to group 1. Meanwhile, the second group can get ready for the training. After the first 
group completes the training exercise, the Instructor Unit only needs to be set to group 2 and the training 
exercise for the second group can begin. 
The configuration is then as follows: 
 

Instructor Unit: 

 

Set to whichever group is training 

Student Unit 1: 

 

Set to group 1, unit A 

Student Unit 2: 

 

Set to group 1, unit B 

Student Unit 3: 

 

Set to group 2, unit A 

Student Unit 4: 

 

Set to group 2, unit B 

Example 

A group consists of four students, but there is only one 

instructor and there are two Misty sets available. 

Summary of Contents for 223.038

Page 1: ...Version 1 2 19 04 19 USER S MANUAL MISTY ELECTRONIC BLINDMASK ORIGINAL USER S MANUAL...

Page 2: ...ge 1 Contents General description 2 Technical specifications 3 Use 4 Misty Mask and Misty Student Unit 4 Misty Instructor Unit 8 More than two Misty Student Units 11 Inspection and maintenance 12 Prec...

Page 3: ...ifferent channels available so that a maximum of six groups can train in the same space The electronic vision restricting mask has been developed to be worn as a primary face mask but it can also be u...

Page 4: ...er 10 mW Battery life approx 10 hours with fully charged battery Dimensions 150 x 100 x 54 mm Weight 430 grams Misty Mask Material Frame Polyurethane hard Polyurethane soft Visor Polycarbonate Transpa...

Page 5: ...how the control elements and connections for the Misty Student Unit Figure 3 1 View from above of Misty Student Unit Figure 3 2 Front and bottom view of Misty Student Unit The Misty Student Unit comes...

Page 6: ...left of the battery see figure 3 2 The easiest way to set the switches is by using a ballpoint pen or a similar pointed object Important The Misty Student Unit must be SWITCHED OFF when adjusting grou...

Page 7: ...unit off and adjust the settings again for the correct group Using the unit Once you have correctly adjusted the settings the unit is ready for use Attach the Misty Student Unit around your waist usi...

Page 8: ...arger to the wall outlet Then connect one of the three charge cables on the Battery Charger to the battery charging connector 6 of the Misty Student Unit The Charging indicator 5 will blink quickly in...

Page 9: ...indicator 2 Battery indicator 3 On Off indicator 4 On Off switch 5 Charging indicator 6 Group switch 7 Group indicators 8 Automated indicator 9 Automated switch 10 Unobstructed vision indicator 11 Un...

Page 10: ...en the unobstructed vision option is switched off the unobstructed vision indicator 10 light will go out In order to be able to adjust the degree of vision available on the Misty Student Units this op...

Page 11: ...arm is also triggered if one of the cables of the Misty Masks is disconnected If this happens the alarm can be turned off via the procedure described above only after the cable has again been connecte...

Page 12: ...tudent Unit 1 Set to group 1 unit A Student Unit 2 Set to group 1 unit A Student Unit 3 Set to group 1 unit B Student Unit 4 Set to group 1 unit B All four Student Units will now work on group setting...

Page 13: ...t with a moist cloth using a mild all purpose household cleaning agent if necessary The casing is not resistant to chemicals such as alcohol thinner or acetone NEVER clean the system using a washing m...

Page 14: ...stem in which case any resulting damage will not be covered by the product guarantee Never use the system if the casing or cables are damaged possibly resulting in increased risk for the instructor or...

Page 15: ...y and switch it on again If you are not able to switch the unit off connect it to the battery charger for 30 seconds disconnect it and then switch the Instructor Unit on again Walkie talkies are also...

Page 16: ...1 2 19 04 19 Page 15 Version 1 2 19 04 19 LION Protects B V Industrieweg 5 5111 ND Baarle Nassau the Netherlands T 31 0 13 507 6800 F 31 0 13 507 6808 E infoEMEA lionprotects com WWW LIONPROTECTS COM...

Reviews: