background image

LN0534E2107B0 

        

         

   

       

Vaporizer Unit Instruction Manual 

 

                        VU-0450N Series 

 

Safety Precautions 

 

   

  Incorrect handling can cause serious injury or death. 

 

(1) 

Before connecting the fittings, check that no damage or defects are found 
on the fittings. Make connections properly and make sure that a leak test is 
conducted before actual operation to prevent liquid and gas from leaking 
into the atmosphere. 

(2) 

DO NOT apply any corrosive fluid to materials exposed to liquid and gas. 
Corrosion may cause liquid or gas to leak into the atmosphere. Please 
confirm the physical properties of liquid or gas before using. 

(3) 

This device is not designed as an explosion-proof structure. DO NOT use 
this device in a place where explosion-proof structures are required. Doing 
so may cause fire or explosion.   

(4) 

Prepare temperature controller unit when operating Vaporizer/Heat Exchanger 
and do not set the temperature over than maximum operating temperature. 
Wring temperature setting may cause fire or destruction of the device. It is 
recommended to add abnormal overheating detector if necessary. 

(5) 

This device must be earthed before use. Otherwise, there is the rink of 
electric shock.   

(6) 

Thermal switch is equipped in Vaporizer/Heat Exchanger to prevent 
overheating. However, the operating temperature of thermal switch would 
vary due to operating conditions and ambient temperature.   

(7) 

Attach/remove connector and terminals, please make sure that power 
supply turning off. It may cause fire or shock hazard.   

 

Incorrect handling can cause medium or

 

slight injury or 

may cause

 

damage to, or loss of, facilities or equipment. 

 

(1) 

Observe the precautions listed in the WARNING (above). 

(2) 

Not using the voltage can cause fire, damage to sensors or malfunction or 
cause electric shock. 

(3) 

This device is not designed to be waterproof. DO NOT locate this product 
outdoors or in a place where it may be splashed with water. Doing so may 
cause fire, trouble or malfunction of this product. 

(4) 

DO NOT modify this product. It may cause fire or other problems. 

(5) 

A  warm-up  period  of  60  minutes  is  recommended  after  reaching  the  set 
temperature. Otherwise, the output gas temperature will be low. 

(6) 

This  device  is  a  precious  device,  please  handle  it  carefully.  Dropping 
down  or  handling  it  carelessly  will  cause  damage.  Please  use  assist 
instrument while moving or setting the device. 

(7) 

Depends on the character of the liquid and process condition, the temperature 
of tube, carrier gas, and the VU, also the flow rate of carrier gas should be 
set properly. 

(8) 

Please use Helium (He) to pressure liquid. It easily lead to bubbles if use N2, 
Ar, O2, etc, that have higher than Helium (He) solubility to pressure. 

(9) 

Regular maintenance is recommended for the steady use of this product. 
This product uses a seal

 

material made from the Kalrez®, in order to 

reduce leakage, Changing the seals annually is recommended. The 
maintenance cycle changes according to precursor type and operating 
conditions, so please consult about the maintenance cycle for the steady use 
of this device. 

 

1. Introduction 

This instruction manual explains the basic operation of Vaporizer unit

 

VU-0450N 

series(Hereafter  called  “VU”).  Please  read

 

through  this  manual  carefully  to 

become familiar with the features of this device.   
 

2. Features 

The VU has the following features. 

(1) 

By using the VU in combination with the liquid mass flow meter 
(Hereafter called “LM”) and the gas mass flow controller (Hereafter 
called “MFC”), precise flow control and effective vaporization can be 
assured. 

(2) 

The functions details of LM are described in the special function 
manual. 

(3) 

It is vaporized by carrier gas (atomizer gas). 
Use a MFC to control the gas flow rate. 

 

3. Specification/ Dimensions 

   

 

 

(1) Specification 

Product name  

Vaporizer 

Model name   

VU-0450N 

Precursor Type   

All type of precursor (In corrosive precursor) 

Power

 

supply  

L01:

 

AC100 to 120V  

L02:

 

AC200 to 240V  

Heater 

L01:800W 
L02:800W 

Thermal switch (Note1) 

Over 230

±

10°C OPEN 

Return operating temperature 200±15°C CLOSE 

Electrical rating (With resistance load) 

AC125V/15A,250V/10A

 

Min:1A 

Maxi mu m  op eratin g t emp eratu re o f  VU  

200°C  

Withstanding pressure (Gauge pressure) 

1 MPa(G) 

Leak integrity  (External  Leak)  

Less than 1.0×10

-11

 

Pa·m

3

/sec (He) 

Fittings  

Precursor inlet  

3.2mm (1/8”) VCR female  

Carrier gas inle t 

6.35mm (1/4”) VCR male  

Vapor outlet  

12.7mm (1/2”) VCR female  

Th ermocou pl e for t emp eratu re cont roll er  

K Type × 1piece  

Reco mmen d ed t emp eratu re cont ro ll er  

PID control  

Wetted materials 

StainlessSteel316L, Au, Ni-Co, Polyimide (SP-1) or PEEK 

Mounting  direction  

Liquid inlet and gas outlet line :

 

horizontal. 

Connector vertical and up. 

(Please confirm the outline dimension drawing)   

Standard

 

accessories  

Thermocouple 
connector 

CMP01-K (RKC) ×1 

Heater/Thermal 
switch connector  

SRCN6A16-7S

 

(JAE) ×1 

LM-VU connect 
cable  

CC-LV-3-3M

 

×1 

 

 

 

 

Note1) The temperature of thermal switch may be different from the temperature of a point of 

     

 

 

 

controlling of VU. 

                         

 

 

 

(2) Dimensions 

(This figure is for "Valve type C: Control valve stand-alone type")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

          Figure1  Externa l  dimens ions   and  components  

 

 

Reviews: