LN0099E2201G0 

         

Solenoid Control Valve 

Instruction Manual 

   

CV-1000 Series

 

  

Safety Precautions 

 

 
Incorrect handling may cause death or injury

 

 

(1)

 

Before connecting the fittings, check that no damage or defects are found on 

the  fittings.  Make  connections  properly  and  make  sure  that  a  leak  test  is 

conducted  before  actual  operation  to  prevent  fluid  from  leaking  into  the 

atmosphere (Hereafter, the measured fluid is called “liquid” or “fluid”).

 

(2)

 

DO NOT

  apply any  fluids corrosive to  the  wetted  materials. Corrosion  may 

cause fluid to leak into the atmosphere. Check the fluid type to be used in advance.

 

(3)

 

This device is not designed as an explosion proof structure. 

DO NOT

 use this 

device in a place where explosion-proof structures are required. Doing so may 

cause fire or explosion.

 

 

Incorrect handling may lead to medium or slight injury or may 

cause damage to, or loss of, facilities or equipment

 

 

(1)

 

Observe the precautions listed in the WARNING (above).

 

(2)

 

Strictly  observe  the  electrical  specifications.  Not  doing  so  may  cause  fire, 

damage to sensors or malfunction.

 

(3)

 

This  device  is  not  designed  to  be  waterproof. 

DO  NOT

  locate  this  device 

outdoors or in a place where it may be splashed with water. Doing so may cause 

fire, trouble, or malfunction of the device.

 

(4)

 

DO NOT

 modify this device. It may cause fire or other problems. 

(5)

 

This  device  is  not  designed  to  handle  hot  swap.  Please  avoid  attaching  and 

removing the power supply connector with the power switched on. Attachment 

and/or removal with the power on may result in failure of the device.

 

(6)

 

This device is a precious device, please handle it carefully. Dropping down or 

handling  it  carelessly  will  cause  damage.  Please  use  assist  instrument  while 

moving or setting the device.

 

(7)

 

Regular maintenance is recommended for steady use of this device 

(Recommended proofreading frequency is once a year).   

 

 

1. Introduction

 

   

This manual explains basic operation of the solenoid control valve CV-1000 series 

(Hereafter,  it  is  called  "CV").  Please  read  through  this  manual  carefully  to 

familiarize yourself with the features of this device. 

 

2. Summary 

   

The CV is a liquid control valve equipped with a solenoid actuator. It can operate 

as a liquid mass flow controller by combining it with a liquid mass flow meter 

(hereinafter referred to as "LM").

 

This device is separated into 2 types depending 

on the way of the connector is attached. Because this device does not include a 

built-in valve control circuit, input is made directly to the solenoid actuator. When 

using this device in combination with the LM, please check the power supply 

voltage and current. 

 

3. Features 

The CV is the following features. 

(1)

 

Equipped with a high-speed, high-performance solenoid actuator.   

(2)

 

Superior corrosion resistant sealing materials make maintenance easy. 

(3)

 

By using a metal case and various types of filters, steady operation can achieve 

even in an environment of high-frequency noise and stationary magnetic field.

 

(4)

 

RoHS compliant

 

 

 
 
 
 
 
 
 
 
 

4. Specification / Dimensions 

(1) Specification 

Name 

Solenoid Control Valve 

Model 

(Both of models at the right are same spec.) 

CV-120*-NC 

CV-1100A (Until 2010) 

Flow rate range 

C2H5OH 

~ 20g/min 

H2O 

~ 10g/min 

Operating pressure 

(When pairing with LM) 

100 to 300 kPa 

Valve operation mode 

Normally closed 

Maximum operating pressure 

300 kPa

(G)

 

Withstanding pressure 

1 MPa

(G)

 

Operating / Storage temperature & 

Humidity 

0 to 50

 

ºC 

 

/  0 to 80%

 

 

 

 

RH  (No dew) 

Materials exposed to liquid 

Stainless steel 316L, Au, PTFE 

Seal Materials / Inner treatment 

Au / Machine finish 

Leak integrity 

Less than 1×10

-11 

Pa

·

 m

3

/sec (He) 

Connector 

HR10-7R-4P (Hirose) 

Control voltage / Current 

0 to 15 VDC / 200mA Max 

Mounting direction 

Free 

Accessories 

CC-LV-3-3M (3000mm) ×1pc 

Weight 

Approximately 750g 

 

(2) Dimensions (CV-1204-NC-2VR7AAA00) 

 

 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
5. Ordering information 
     

  CV-120* – NC – 2VR7 AAA00 

     

[1]

 

 

               

[2]

 

  [3]

 

  [4] 

  
[1] Series model: CV: Control Valve 

 

CV-1204 (Connector : Upward) 

    CV-1207 (Connector : Downstream side) 
[2] Valve mode 

   

NC: Normally close (No treatment)   

[3] Fitting 

   

2VR7 : 3.2 mm (1/8”) VCR male    Fitting Distance 77 mm 

   

2SW9 : 3.2 mm (1/8”) SWL male    Fitting Distance 92.4 mm 

   

4SW9 : 6.35 mm (1/4”) SWL male    Fitting Distance 88.4 mm 

   

※ Please consult for more information. 

[4] Optional 

   

Default setting is labeled “AAA00”. Please consult for more information. 

 

Connector
HR10-7P-4S(73)(HRS)

Connector
HR10-7P-4P(73)(HRS)

13

145

5.3

(28.5)

Cable

CC-LV-3

7

18

7

CV-1100

20

37

20

77

32

9.5 18

9.5

2xM4 Depth 5

3.2(1/8)VCR male