LINOVISION IPC-VEC754PF-E Quick Start Manual Download Page 9

                                                                           

 

 

5

 

 

Step 3 

Draw out the cable exit and four screw holes in the installation position according to the device 
pedestal. Dig the four plastic expansion bolt holes and cable exit. Insert the four plastic 
expansion bolts into the screw holes  

 

Step 4 

Adjust the camera pedestal to the proper position and then draw the cable through the cable exit 
you just dug in the ceiling (wall).  Line up the four screw holes in the device pedestal to the four 
plastic expansion bolt holes in the installation position. Put the four self-tapping screws in the 
device pedestal and then use the screwdriver to secure the screws in the four plastic expansion 
bolts firmly.

 

 

Step 5 

Adjust the device position and line up the three inner hexagon screws of the device to the three 
holes of the installation position. Put the three inner hexagon screws into the screw holes at the 
bottom of the pedestal. Use the inner hexagon screwdriver to fix firmly. Connect the GND to the 
ground wires to improve stability. See Figure 2-3. 
 

 

With IR light                                       Without IR light  

Figure 2-3 

 

Step 6 

Adjust the X-Y-Z axis module to turn the device to the proper monitor angle. Please follow the 
steps listed below to adjust. See Figure 2-4. 
Please note, for the dome of the IR light, you can skip step a) and step e). 

z

  a): Slightly push the two sides to squeeze the plastic hook so that you can take off the dome 

enclosure.  

z

  b):Slightly loose the screws at the two sides of the X-Y-Z module manually, you can adjust 

the module tilt rotation angle (15

°~

90

°

). 

z

  c):Slightly loose the screw of the pressing slice, you can adjust the video rotation angle of 

the module (0

°~

355

°

Summary of Contents for IPC-VEC754PF-E

Page 1: ...HD Vandal Proof IP Dome Camera Quick Start Guide Version 3 0 0...

Page 2: ...ortation security Heavy stress violent vibration or water splash are not allowed during transportation storage and installation 3 Installation Do not apply power to the camera before completing instal...

Page 3: ...there is too much dust please use the water to dilute the mild detergent first and then use it to clean the device Finally use the dry cloth to clean the device Please put the dustproof cap to protect...

Page 4: ...and Dimension 2 2 Installation 4 2 1 Device Installation 4 2 2 SD Card Installation 7 2 3 Lens Adjustment 7 3 Quick Configuration Tool 9 3 1 Overview 9 3 2 Operation 9 4 Web Operation 12 4 1 Network...

Page 5: ...dio signal It can receive the analog audio signal from the pickup AUDIO OUT Audio output port RCA Output audio signal to the devices such as the sound box 12V DC AC24V Power input port Power port Inpu...

Page 6: ...put port It works with the ALARM_COM port Blue RESET It is to restore factory default setup When the device is working properly please connect the blue cable restore default setup port to the orange c...

Page 7: ...3 Figure 1 3...

Page 8: ...below 2 1 Device Installation Step 1 Use the inner hexagonal wrench provided to loose the three inner hexagon screws in the dome cover and then open the cover The device is shown as in Figure 2 1 Fig...

Page 9: ...ree inner hexagon screws of the device to the three holes of the installation position Put the three inner hexagon screws into the screw holes at the bottom of the pedestal Use the inner hexagon screw...

Page 10: ...Figure 2 4 Please note the screws in the following figure are the optical adjustment component Please make sure it is outward and do not allow it to touch the X Y Z axis module See Figure 2 5 Figure...

Page 11: ...out IR light Figure 2 7 2 3 Lens Adjustment Step 1 Slightly loose the screw B manually and then turn the screw B slowly Adjust the lens focus distance to the proper position according to the monitor v...

Page 12: ...8 With IR light Without IR light Figure 2 8...

Page 13: ...applies to the IP addresses in the same segment 3 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 3 1 In the device list interface you can view device...

Page 14: ...terface Or you can select an IP address and then click the Login button to go to the login interface See Figure 3 4 In Figure 3 4 you can view device IP address user name password and port Please modi...

Page 15: ...11 Figure 3 5 For detailed information and operation instruction of the quick configuration tool please refer to the Quick Configuration Tool User s Manual included in the resources CD...

Page 16: ...ively IPC default IP address is 192 168 1 108 Subnet mask is 255 255 255 0 Gateway is 192 168 1 1 z Use order ping IP camera address to check connection is OK or not 4 2 Login and Logout Open IE and i...

Page 17: ...se click OK button system can automatically install the control When system is upgrading it can overwrite the previous Web too If you can t download the ActiveX file please check whether you have inst...

Page 18: ...14 Figure 4 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction...

Page 19: ...dly use period EFUP period the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe envi...

Reviews: