It  may  happen  that  in  the  case  of  400V  models,  the  direction  of  rotation  of  the  motor  is 
incorrect.  This is immediately recognisable. The mounted motor protection plug is appointed 
with a phase reverse. Please pull the plug off. In front of the plug you can exchange the two 
live poles with a screwdriver. The rotational direction will be corrected. 

 
Maintenance

 

All water aerators supplied require little or no maintenance.  From time to time simply clean all 
parts of the apparatus.  To do this you must remove the apparatus from the water.  Warning 

– 

first disconnect from the mains! 
 
If the apparatus is supplied with a screen, this, in particular, should be kept clean, for perfect 
functioning of the apparatus can only be assured if the surface of the screen is clean. 
At  least  once  a  year,  the  apparatus  should  be  examined  for  perfect  running  of  the  propeller 
and, in the case of submersible motors, for the condition of the motor’s watertight flanges.  If 
you experience any problems, please contact us. 
 

Guarantee 

This apparatus carries a 12-month guarantee   of proper use.   A change to the  apparatus or 
opening of the motor parts is prohibited and renders the guarantee invalid.  We can accept no 
liability for damage and losses incurred as a result of breakdown of the aerator.  The operator 
is  advised  to  obtain  protection  (an  alarm  system),  which  would  alert  them  to  any  eventual 
breakdown of the apparatus. 
 

Further Information

 

We would advise you that, in accordance with product liability law, we  do  not accept liability 
for  damage  caused  by  our  apparatus,  if  the  information  and  advice  given  within  these 
operating instructions has not been followed. 
The aerator should never be pulled, carried or fixed into place, by the connection cable.  Only 
suitably  qualified  persons  should  carry  out  replacement  of  the  connection  cable.      The 
connection lead should be no lighter than a rubber hose HO7 RN-F (EN 60335-2-41).  Avoid 
wear and tear on the connection cable! 
The electric lead should be kept in an area where there is no risk of flooding and should be 
protected  from  damp.    Connection  cable  and  plug  should  be  examined  for  damage  before 
use. 
The  aerator  should  not  be  operated  out  of  water!  In  the  event  of  aerator  defects,  repairs 
should be carried out only by the manufacturer or by an authorised dealer.  In addition, only 
original spare parts should be used. 
The  aerator  is  fitted  with  a  rubber  over-current  device,  designed  to  protect  the  motor  from 
overload. It is fitted next to the round site plug, and has a reset button. It is not weatherproof, 
and  should  be  protected  from  rain  and  direct  sunlight.  If  the  overcurrent  device  trips  out  the 
power  to  the  aerator,  investigate  the  cause  promptly.  Repeated  pushing  of  the  reset  button, 
may  damage  the  motor.  Consult  your  supplier  about  servicing  the  motor.  Removal  of  the 
overcurrent device will invalidate the warran 

 
 
 
 

 

 
 

OXYPLUS 0,55 kW + 0,75 kW 

 

 

                                          

 

 

    

Montage

 

Die  Schwimmkörper  für  das  Anreicherungssystem  liegen  lose  bei.  Bitte  schieben  Sie  diese  in 
den Hauptbehälter ein und befestigen Sie die Schwimmer mit je zwei  M8-Schrauben 

– die Un-

terlegscheiben  nicht  vergessen!  Anschließend  drücken  Sie  bitte  die  Schutzstopfen  in  die 
Schwimmkörper.

 

 
An der Kopfseite des Behälters finden Sie ein Gewinde. Hier schrauben Sie bitte den beiliegen-
den  Entlüftungsbogen  lose  ein.  Bitte  verwenden  Sie  kein  Dichtungsmittel 

–  der  Bogen  muss 

sich  beim  Zuwasserlassen  des  Gerätes  zur  Luftentweichung  aus  dem  Innenraum  noch  nach 
oben drehen lassen. Während des Betriebes muss der Bogen in das Wasser reichen.

 

 
Zur Befestigung des Gerätes auf Ihrem Gewässer benötigen sie zwei Halteseile, welche Sie an 
der Kopfseite durch die vorgesehene Durchführungen ziehen können. 
 

      Den Sauerstoff-Zuleitungsschlauch verbinden Sie bitte mit dem vorgesehenen Anschluss  
      auf  dem Gerät. 

 
 

 

Inbetriebnahme 

Nach  abgeschlossener  Montage  setzen  Sie das  komplette  Gerät  in Ihr  Gewässer.  Die Luft  im 
Gerät entweicht langsam 

– unbedingt den Entlüftungsbogen aus dem Wasser ragen lassen und 

nach vollständigem Entweichen der Luft, Bogen wieder ins Wasser drehen. Mit Hilfe Ihrer Seile 
können  Sie  das  Gerät  in  die  gewünschte  Stellung  bringen.  Der  Wasseraustritt  ist  in  Richtung 
der Halteseile! Bitte Drehrichtung des Motors unbedingt überprüfen!

 

 
In die Sauerstoff-Zuleitung zum Gerät montieren Sie eine Sauerstoff Durchflussmengenmesser 
(nicht im Lieferumfang enthalten). Sie können entsprechend der gelieferten Gerätegröße 1,0 

– 

1,5 m³/h zuleiten! Oxyplus 0,55 kW 

– max. 17l/m

 

                                             0,75 kW 

– max. 25l/m 

 
 

 

Wartung 

Das  Eintragssystem 

OXYPLUS

  arbeitet  weitgehend  wartungsfrei.  Lediglich  am  Einlaufsieb  ist 

eine Verstopfung möglich. Das Sieb muss daher von Zeit zu Zeit gereinigt werden. Im System 
ist eine Verstopfung ausgeschlossen 

– das Öffnen des Systems ist daher nicht erforderlich.

 

 

 

 