E1400 V1 Rev. D Installation Guide
6 Description of the connectors / Interfaces
6.1 X1-V1 Rev. D
X1
DC Busbar/ Regeneration Resistor
DC+:
DC
DC-:
DC busbar -
RR+:
Positive connection for Regeneration Resistor
RR-:
Negative connection for Regeneration Resistor
Screw Terminals:
- Tightening torque: 0.7 - 0.8 Nm
- Use a cross-head screw driver (PH1)
- Use 60/75°C copper conductors only
- Conductor cross-section: 0.25 – 4 mm
2
(depends on Motor current) / AWG 24 -12
- Stripping length 10mm
6.2 X30-V1 Rev. D
X30
Motor Supply Mains
L1 – L3: 3x400 / 3x480VAC 50/60 Hz
PE:
PE, Protective Earth
Screw Terminals:
- Tightening torque: 0.7 - 0.8 Nm
- Use a cross-head screw driver (PH1)
- Use 60/75°C copper conductors only
- Conductor cross-section: 2.5 – 4 mm
2
(depends on Motor current) / AWG 24 -12
- Stripping length 10mm
6.3 X2-V1 Rev. D
X2
Motor Phases
PE:
Protective Earth and Cable Shield
W:
Motor Phase W
V:
Motor Phase V
U:
Motor Phase U
KTY+:
Temperature Sensor KTY+
KTY-:
Temperature Sensor KTY-
Screw Terminals:
- Tightening torque: 0.7 - 0.8 Nm
- Use a cross-head screw driver (PH1)
- Use 60/75°C copper conductors only
- Conductor cross-section: 0.25 – 4 mm
2
(depends on Motor current) / AWG 24 -12
- Stripping length 10mm
Attention:
The type of connector and pin assignment on V1 Rev. D and V2 drives
is different from V1 (Rev. A-C) drives (different coding)!
NTI AG / LinMot
®
www.LinMot.com
Page 9/24