C1400 Installation Guide
preliminary
5.3 X2
X2
Motor Phases
PE:
Protective Earth
W:
Motor Phase W
V:
Motor Phase V
U:
Motor Phase U
T+:
Temperature Sensor KTY+
T-:
Temperature Sensor KTY-
B+:
Motor Brake+
B-:
Motor Brake-
Spring Cage Connector
The Shield of the motor cable has to be mounted with a surface as large as possible (low
ohm, low impedance). Use an EMC shield clamp for fixing.
Attention:
An isolated thermistor is necessary! Especially LinMot D01 and D02
Motors can not be connected!
Screw Terminals:
- Spring-cage connector
- Use 60/75°C copper conductors only
- Conductor cross-section: 0.2 – 2.5 mm
2
(depends on Motor current) / AWG 24 -12
- Stripping length 10mm
LinMot Article Number: 0150-3605
Operating of the drive is only allowed with the above article!
No other type of connector shall be used!
5.4 X3
X3
Motor Encoder (Motor Link C) / Not available on -CI drives!
8
15
7
14
6
13
5
12
4
11
3
10
2
9
1
case
Motor Link C -
Motor Link C +
do not connect
do not connect
do not connect
do not connect
GND
do not connect
GND Sense
+5V Sense
Cos-
Cos+
Sin-
Sin+
+5V
shield
DSUB-15 (m)
Motor Link C is a high speed serial communication protocol to the motor encoder.
Page 10/21
www.LinMot.com
NTI AG / LinMot
®