C1450-XX-VS-1S Installation Guide
NTI AG / LinMot
®
www.LinMot.com
Page 9/24
5
Description of the connectors / Interfaces
5.1
PE
PE
Protective Earth
PE
•
Use min. 4mm
2
(AWG11)
•
Tightening torque: 2Nm (18 lbin)
5.2
X30
X30
Motor Supply Mains / Regeneration
RR-
Regeneration Resistor
RR+
Regeneration Resistor
N:
Neutral (TN system with grounded Neutral)
L1:
Line 1 (1x230VAC (+-10%) 50/60Hz / use slow blow 6A fuse)
PE:
PE, Protective Earth
Line filter is integrated into the drive.
Screw connector
Screw Terminals:
- Tightening torque: 0.5 - 0.6 Nm
- Screws: M3
- Use 60/75°C copper conductors only
- Conductor cross-section: 2.5mm2 (AWG 12)
- Stripping length 7mm
LinMot Article Number: 0150-3607 (DC01-C1400/X30)
Operating of the drive is only allowed with the above article!
No other type of connector shall be used!