5.2 Connector Wiring Linear Motor
View: Motor connector, plug side
Connector wiring
Linear Motor:
C-Connector
Wire colour
Motor cable
Ph 1+ / Ph A
A
red
Ph 1- / Ph B
B
pink
Ph 2+ / Ph C
C
blue
Ph 2- / Ph D
D
grey
+5VDC
E
white
GND
F
inner shield
Sin
G
yellow
Cos
H
green
Temp.
L
black
Shield
Housing
outer shield
5.3 Connector Wiring Rotary Motor
View: Motor connector, plug side
Connector wiring
Rotary Motor:
R-Connector
Wire colour
Motor cable
Ph 1+ / Ph A
1
red
Ph 1- / Ph B
2
pink
Ph 2+ / Ph C
3
blue
Ph 2- / (-)
4 (not connected)
grey
+5VDC
A
white
GND
B
inner shield
Sin
C
yellow
Cos
D
green
Temp.
E
black
Shield
Housing
outer shield
Motor extension cables are double shielded. The two shields of the extension cable are
insulated from each other. The inner shield of the extension cable may only be connected to
GND (no contact to the outer shield).
The outer shield must be connected to the shield of the connector.
2
4
1
A
B
C
D
E
3