31
1
)
After setting the parameters, click
【
Apply
】
to take effect.
2
)
If you change the IP address, the webpage will no longer responds, please enter the
new IP address in web browser to access the device.
3
)
If the system USES DHCP to obtain IP when device boots up, and the network
address of the DHCP Server is the same as the network address of the system LAN,
then after the system obtains the DHCP IP, it will add 1 to the last bit of the network
address of LAN and modify the IP address segment of the DHCP Server of LAN. If the
DHCP access is reconnected to the WAN after the system is started, and the network
address assigned by the DHCP server is the same as that of the LAN, then the WAN
will not be able to obtain IP access to the network
9.11
Network >> service port
This page provides the settings of webpage login protocol, protocol port and RTP port.
Picture 28 - Service port setting interface
Table 15 - Server Port
parameter
description
Web server type
Restart after setting takes effect. Optional web login as
HTTP/HTTPS
Web login timeout The default is 15 minutes, the timeout will automatically log out of
the login page, and you need to log in again
Web page
automatic login
No need to enter the user name and password after the timeout, it
will automatically log in to the web page.
HTTP port
The default is 80, if you want system security, you can set other
port
Such as: 8080, web page login: HTTP://ip:8080
HTTPS port
The default is 443, same as HTTP port usage