LinkAYL LK-CP611 Manual Download Page 3

Matching

 

Code

 

 

Power

 

the

 

controler

 

on,

 

keep

 

pressing

 

STOP

 

button

 

on

 

the

 

controler

 

for

 

5

 

seconds,

 

LED

 

flashes

 

3

 

times

 

and

 

turns

 

off

 

 

Press

 

[UP]

 

within

 

15

 

seconds

 

 

LED

 

flashes

 

3

 

times

 

and

 

turns

 

off,

 

code

 

matched

 

successfully

 

 

Clearing

 

Single

 

Code

 

 

Power

 

the

 

controler

 

on

 

 

Keep

 

pressing

 

STOP

 

key

 

on

 

the

 

controler

 

for

 

5S,

 

LED

 

flashes

 

3

 

times

 

and

 

turns

 

off

 

 

Press

 

DOWN

 

button

 

on

 

the

 

remote

 

within

 

15

 

seconds

 

 

LED

 

flashes

 

3

 

times

 

and

 

turns

 

off,

 

code

 

cleared

 

successfully

 

 

Clearing

 

All

 

Codes

 

 

Power

 

the

 

controler

 

on,

 

keep

 

pressing

 

STOP

 

and

 

DOWN

 

button

 

on

 

the

 

controler

 

for

 

5

 

seconds

 

 

LEDs

 

flash

 

3

 

times

 

and

 

turn

 

off,

 

all

 

the

 

codes

 

will

 

be

 

deleted

 

after

 

this

 

operation

 

 

Signal

 

Control

 

 

Manual

 

signal.

 

Control

 

the

 

window

 

by

 

the

 

buttons

 

on

 

itself,

 

external

 

dry

 

contact

 

manual

 

switch

 

and

 

RF

 

remote

 

 

Cascaded

 

signal.

 

As

 

a

 

master

 

controler

 

sends

 

signal

 

to

 

the

 

slave

 

controler,

 

can

 

also

 

be

 

used

 

as

 

slave

 

controler

 

to

 

receive

 

the

 

signal

 

from

 

the

 

master

 

controler

 

to

 

drive

 

the

 

window

 

 

Fire

 

signal.

 

Capable

 

of

 

receiving

 

a

 

signal

 

from

 

fire

 

center,

 

smoke

 

sensor,

 

gas

 

detector

 

open

 

the

 

window

 

automatically,

 

send

 

feedback

 

signal

 

to

 

fire

 

centre

 

 

Rain

 

signal.

 

After

 

receiving

 

the

 

signal

 

of

 

rain

 

sensor

 

close

 

the

 

window

   

 

Temperature/humidity

 

signal.

 

Control

 

the

 

window

 

by

 

processing

 

external

 

temperature/humidity

 

sensor

   

 
 
 
 

Signal

 

and

 

Priority

 

Priority

 

1

 

2

 

3

 

4

 

Signal

 

Manual

 

Signal

 

Fire

 

Signal

 

W/R

 

Signal

T/H

 

Signal

   

Device

 

Panel

 

buttons

 

Manual

 

switch

 

Remote

 

Master

 

controler

Smoke

 

sensor

 

Gas

 

detector

 

Wired

 

wind

 

/rain

 

sensor

 

temperature

 

sensor

 

humidity

 

sensor

 

 

Reset

 

and

 

Shielding

 

 

After

 

manual

 

signal

 

processed

 

controler

 

resets

 

or

 

receives

 

input

 

signal

 

in

 

real

 

time

   

 

After

 

processing

 

the

 

signal

 

from

 

fire

 

centre,

 

smoke

 

sensor

 

or

 

gas

 

detector,

 

the

 

controler

 

immediately

 

shields

 

all

 

the

 

input

 

signals,

 

the

 

controler

 

must

 

be

 

reset

 

by

 

pressing

 

K1

 

manually

 

 

After

 

wired

 

rain

 

sensor

 

signal

 

processed,

 

the

 

controler

 

shields

 

lower

 

priority

 

signal,

 

only

 

receives

 

the

 

higher

 

priority

 

signal

 

until

 

reset

 

or

 

manual

 

signal

 

processed

 

 

After

 

T&H

 

sensor

 

signal

 

processed

the

 

controler

 

is

 

in

 

the

 

reset

 

state

 

 

If

 

the

 

controler

 

is

 

not

 

connected

 

to

 

a

 

temperature

 

and

 

humidity

 

sensor,

 

the

 

T/H

 

port

 

must

 

be

 

shielded

 

(put

 

option

 

switch

 

“Y”

 

position),

 

otherwise

 

it

 

will

 

affect

 

the

 

control

 

of

 

other

 

input

 

signal

 

 

Cascaded

 

Control

 

 

Can

 

be

 

used

 

as

 

a

 

master

 

controler,

 

a

 

slave

 

controler

 

or

 

play

 

a

 

dual

 

role

 

of

 

master

 

&

 

slave

 

controler

 

at

 

the

 

same

 

time.

   

 

As

 

a

 

master

 

controler,

 

connects

 

to

 

the

 

motors

 

or

 

slave

 

controlers

 

to

 

drive

 

them

 

 

As

 

a

 

slave

 

controler,

 

input

 

terminals

 

S+

 

and

 

S

‐ 

are

 

connected

 

to

 

the

 

output

 

terminals

 

M+

 

and

 

M

‐ 

of

 

the

 

master

 

controler

 

to

 

receive

 

the

 

instructions

 

to

 

drive

 

motors,

 

or

 

drive

 

the

 

motors

 

independently

 

 

Play

 

a

 

dual

 

role

 

of

 

master

 

&

 

slave

 

controler,

 

not

 

only

 

controlled

 

by

 

higher

level

 

controler,

 

but

 

also

 

drive

 

motors

 

or

 

lower

level

 

controlers

 

independently

   

 

No

 

matter

 

master,

 

slave

 

or

 

both,

 

it

 

can

 

process

 

all

 

the

 

external

 

signals

 

such

 

as

 

manual

 

switch,

 

remote

 

and

 

sensors

 

 
 