Matching
Code
Power
the
controler
on,
keep
pressing
STOP
button
on
the
controler
for
5
seconds,
LED
flashes
3
times
and
turns
off
Press
[UP]
within
15
seconds
LED
flashes
3
times
and
turns
off,
code
matched
successfully
Clearing
Single
Code
Power
the
controler
on
Keep
pressing
STOP
key
on
the
controler
for
5S,
LED
flashes
3
times
and
turns
off
Press
DOWN
button
on
the
remote
within
15
seconds
LED
flashes
3
times
and
turns
off,
code
cleared
successfully
Clearing
All
Codes
Power
the
controler
on,
keep
pressing
STOP
and
DOWN
button
on
the
controler
for
5
seconds
LEDs
flash
3
times
and
turn
off,
all
the
codes
will
be
deleted
after
this
operation
Signal
Control
Manual
signal.
Control
the
window
by
the
buttons
on
itself,
external
dry
contact
manual
switch
and
RF
remote
Cascaded
signal.
As
a
master
controler
sends
signal
to
the
slave
controler,
can
also
be
used
as
slave
controler
to
receive
the
signal
from
the
master
controler
to
drive
the
window
Fire
signal.
Capable
of
receiving
a
signal
from
fire
center,
smoke
sensor,
gas
detector
open
the
window
automatically,
send
feedback
signal
to
fire
centre
Rain
signal.
After
receiving
the
signal
of
rain
sensor
close
the
window
Temperature/humidity
signal.
Control
the
window
by
processing
external
temperature/humidity
sensor
Signal
and
Priority
Priority
1
2
3
4
Signal
Manual
Signal
Fire
Signal
W/R
Signal
T/H
Signal
Device
Panel
buttons
Manual
switch
Remote
Master
controler
Smoke
sensor
Gas
detector
Wired
wind
/rain
sensor
temperature
sensor
humidity
sensor
Reset
and
Shielding
After
manual
signal
processed
controler
resets
or
receives
input
signal
in
real
time
After
processing
the
signal
from
fire
centre,
smoke
sensor
or
gas
detector,
the
controler
immediately
shields
all
the
input
signals,
the
controler
must
be
reset
by
pressing
K1
manually
After
wired
rain
sensor
signal
processed,
the
controler
shields
lower
priority
signal,
only
receives
the
higher
priority
signal
until
reset
or
manual
signal
processed
After
T&H
sensor
signal
processed
,
the
controler
is
in
the
reset
state
If
the
controler
is
not
connected
to
a
temperature
and
humidity
sensor,
the
T/H
port
must
be
shielded
(put
option
switch
“Y”
position),
otherwise
it
will
affect
the
control
of
other
input
signal
Cascaded
Control
Can
be
used
as
a
master
controler,
a
slave
controler
or
play
a
dual
role
of
master
&
slave
controler
at
the
same
time.
As
a
master
controler,
connects
to
the
motors
or
slave
controlers
to
drive
them
As
a
slave
controler,
input
terminals
S+
and
S
‐
are
connected
to
the
output
terminals
M+
and
M
‐
of
the
master
controler
to
receive
the
instructions
to
drive
motors,
or
drive
the
motors
independently
Play
a
dual
role
of
master
&
slave
controler,
not
only
controlled
by
higher
‐
level
controler,
but
also
drive
motors
or
lower
‐
level
controlers
independently
No
matter
master,
slave
or
both,
it
can
process
all
the
external
signals
such
as
manual
switch,
remote
and
sensors