6 –  Door Operator / CDO / LC- 3158 Rev.B

5.5  Installation of the emergency hand chain

(for operators with emergency hand chain)

Information:

To ensure that they work correctly, the 
chain links must not be twisted.  

 

 

Join the ends of the emergency hand chain together 
with a chain connecting link.

Warning! 

To avoid damage to the operator and 
the door, the emergency hand chain 
must be safely secured (for example in a 
‘chain keep’ ) while the door is operated 
electrically.

6.1 Preparation

Warning! 

To avoid damage to the operator, the 
 following points must be observed:

-  The types of cable and their diameters must be selected 

according to current regulations.

-  The nominal currents and the type of connection must 

correspond to those on the motor type plate.

-  The drive details must agree with the  connected loads.

  

Information: 

When operated with electronic control units, 
the corresponding start-up instructions and 
circuit diagrams must be complied with.

5.   Installation

6.   Initial Operation

6.2  Motor Connections

‘Standard’ 3ph Motor Connection

3 x 400V Star connection (standard)

The motor should be configured as shown above 

for connection to a 3 x 400V control panel.

'400V / 690V' 3ph Motors Connection

3 x 400V Delta connection (CDO375 & CDO400)

The CDO375 & CDO400 should be configured as shown 

above for connection to a 3 x 400V control panel.

Summary of Contents for CDO Series

Page 1: ... Manor Park Runcorn Cheshire WA7 1TS T 44 0 1928 579050 F 44 0 1928 579259 www linkcontrols co uk enquiries linkcontrols co uk Warning Please read these instructions fully before installation Link Controls Instructions for Rolling Door Operator type ...

Page 2: ...opriate safety equipment Capable of recognising the dangers associated with installation Only qualified and trained electricians may connect the operator and carry out electrical maintenance Qualified and trained electricians fulfil the following requirements knowledge of the general and specific safety and accident prevention regulations knowledge of the relevant electrical regulations trained in...

Page 3: ...e fluctuations EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments EN 61000 6 3 Electromagnetic compatibility EMC Part 6 3 Generic standards Emission standard for residential commercial and light industrial environments Machinery guidelines EN 60204 1 Safety of machinery electrical equipment of machines part 1 general requirements EN 12100...

Page 4: ...er a lengthy storage period all connections have been carried out correctly the direction of rotation of the drive motor is correct all motor protective devices are active no other sources of danger exist the installation site has been cordoned off over a wide area Information The relevant instruction for the door must be observed when fitting the drive to the door a suitably rated mains protectio...

Page 5: ...n failure CDO Operator Information Link Controls Ltd constantly strives to improve the quality of its goods and as such reserves the right to replace modify products without prior notification Any examples given are intended for guidance only Self Aligning Flange Bearing End Plate Shutter Barrel Drive End Shaft Weld into Position Plate Wheel Drive Chain Sprocket End Plate Self Aligning Flange Bear...

Page 6: ...ypes of cable and their diameters must be selected according to current regulations The nominal currents and the type of connection must correspond to those on the motor type plate The drive details must agree with the connected loads Information When operated with electronic control units the corresponding start up instructions and circuit diagrams must be complied with 5 Installation 6 Initial O...

Page 7: ...l operate should the motor be overloaded The Hand Chain Interlock provides a means of control circuit isolation to prevent electrical operation whilst the door is being operated manually Warning To ensure compliance with BS 7671 wiring regulations IET the Thermal Trip must be connected into the relevant controller safety circuit Stop circuit Note For operators with a disengage clutch the disengage...

Page 8: ...he CLOSED direction The operator must close the door Drive the door in the OPEN direction The operator must open the door Information If the door s direction of travel does not correspond to the commands keyed in then the direction of rotation must be changed Instructions for changing the direction of rotation are given in the control unit operating manual After this the direction of travel must b...

Page 9: ...l unit operating manual for instructions on setting the limit end positions A B Wiring allocation AVE absolute value encoder plug The numbers on the plug are also the wire numbers 4 Safety circuit input N C 5 RS 485 B 6 GND 7 RS485 A 8 Safety circuit output N C 9 7 18V DC AVE absolute value encoder plug terminal 7 12 C Thermal element in the drive D Manual emergency control emergency crank or emer...

Page 10: ... site During maintenance works or in the case of an electrical failure the door can be moved towards the OPEN or CLOSED positions with the help of the emergency manual override equipment Information If the door is moved beyond the CLOSED or OPEN end positions the operator may no longer be activated electrically place the door back into a normal position before attempting powered operation Operatio...

Page 11: ...ches Check for noises and oil leaks Check the mounting of the operator for corrosion Check the housing for damage Operation with emergency floor level hand chain KE Releasing Gently pull the cable with the red handle downwards as far as possible The control voltage will be interrupted and the door can no longer be operated electrically Release the emergency hand chain from its fixing Move the door...

Page 12: ...000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity standard for industrial environments EN 61000 6 3 Electromagnetic compatibility EMC Part 6 3 Generic standards Emission standard for residential commercial and light industrial environments EN 60335 2 103 Particular requirements for drives for gates doors and windows The relevant technical documentation is compiled in ac...

Reviews: