In Depth Command Description: C017
Interrogate and Control Latched Outputs On/Off
This command allow the user to turn each of the logical output lines on or off or check the
current state the line is in. Note that the outputs are buffered with open drain drivers; therefore
on means that the line is pulled to ground (will sink current) and off means that the output is in a
high impedance state and will not sink any current. Interrogation is accomplished by entering only
the line requested. The RLC-1 will return either a 'F' if the line is off, or 'N' if the line is on.
Description
Command
CW Response
Out #1 On/Off
C017*1 $*
CW BEEP RSP
#2 "
C017*2 $*
#3 "
C017*3 $*
#4 "
C017*4 $*
#5 "
C017*5 $*
Out #1 Check
C017*1*
'F' if Line is OFF
#2 "
C017*2*
#3 "
C017*3*
'N' if Line is ON
#4 "
C017*4*
#5 "
C017*5*
Parameters:
$ - 1 To turn line ON
$ - 0 To turn line OFF
Error Message:
If the format is not correct, the RLC-1 will send a "E" error code.
ER1 - Not a Valid Output Line
ER2 - Not a Valid Output Condition, Must be a 0 or 1