Before You Start

Check  for  and  remove  obstacles  in  path  of  the  desk  top.  Before 

fir

st  use,  the  control 

unit must register the lowest point of elevation. Do reset as section 1.2. Under normal 

conditions the system communicates internally and knows the position of each column. 

DANGER

Improper power connection of the equipment can result in a risk of electric 

shock. Check with a qualified electrician 

for any concerns.

This product does NOT require grounding to earth. This product is double 

insulated and equipped with a non-polarized plug and 2-conductor cord. The 

plug  must  be  plugged  into  an  appropriate  building  outlet  that  is  properly 

installed  in  accordance  with  all  local  codes  and  ordinances.

CAUTION

When  the  power  cord  is  plugged  in,  the  electrical  control  devices  are 

operational.

NOTICE

When  disconnecting  components  such  as  the  control  box,  bus  cable  or 

the  handset,  the  strain  relieve  hook  must  be  pressed  before  removing  the 

connector.  When  inserting  the  connector,  an  audible  “click”  indicates  that 

the strain relieve hook has correctly re-engaged.

In  case  of  a  power  failure  or  if  the  power  cord  is  unplugged  during  the 

movement of the drives, a manual reset may be necessary. See section 1.2.

The control unit can be damaged by power surges. Unplug the power cord 

during a thunderstorm or if you do not intend to use the desk for a longer 

period.

1

c o m fo rt  &  e rg o n o m ic s  

lin

e rg o

Summary of Contents for GOTLAND COMPACT-2

Page 1: ...USER MANUAL Frame ERGO 2 COMPACT 2 GOTTFIRD Office desk SCANDIC GOTLAND 1h 1 14 linergo linergo lv 371 29114991 www linergo lv c o m fo rt e rg o no m ic s linergo Assembling time Necessary tools...

Page 2: ...ts included A x 2 E x 2 F x 18 G x 8 H x 4 x 1 K x 4 B x 4 C x 2 D x 2 Z x 1 P x 1 R x 1 4 5 25 4 5 15 T x 2 3 15 2 14 linergo linergo lv 371 29114991 www linergo lv c o m fo rt e rg o no m ic s liner...

Page 3: ...A A C C D 3 14 linergo linergo lv 371 29114991 www linergo lv c o m fo rt e rg o no m ic s linergo H H G G G K R P E T F F F Z D B x4...

Page 4: ...ns further please use your own good judgment You will nd important safety information in a variety of forms Safety messages are preceded by a safety alert symbol and one of three signal words DANGER W...

Page 5: ...d with the power supply Make sure that the cord is not damaged before usage Do not operate the stand if the power cord is damaged A damaged cord shall only be changed by authorised personnel Do not ex...

Page 6: ...utdoors Do not exceed the maximum intended load To minimize the risk of squeezing or pinching ensure that there is at least 2 5 cm one inch safety margin between the desk top and items above or below...

Page 7: ...AL INFORMATION Load shall be evenly distributed Speed may vary with load Standards Certi cates The complete stand base is developed to harmonize with standard requirements requirements EN 1730 Furnitu...

Page 8: ...t be plugged into an appropriate building outlet that is properly installed in accordance with all local codes and ordinances CAUTION When the power cord is plugged in the electrical control devices a...

Page 9: ...Press the handset up button and continue to hold until desired desktop height is reached 1 1 2 Downward Desktop Movement This function enables the downward adjustment of the work surface To change it...

Page 10: ...mory position press the up or down button for a minimum of 5 seconds How to set memory end positions 1 Drive your desk to the level you want to store 2 Press both buttons 3 times 0 5 1 second between...

Page 11: ...ng the buttons and the desk will slowly move the lowest point possible The reset is complete when the desk has stopped at the lowest point The desk stand is ready for normal use 1 3 Collision Detectio...

Page 12: ...nspect columns for loose connections and damaged plugs wires Inspect control box for loose connections and damaged plugs wires The control box and the handset are sealed and maintenance free Repairs C...

Page 13: ...utes of inactivity If this limitation is exceeded the desk will become inoperable until the control box resets automatically Overheating protection The desk will become inoperable if the overheating p...

Page 14: ...s Follow install instructions and perform a reset The desk only moves short distances Make sure that the desk is not overloaded Unload the desk If the problem remains replace the control box The desk...

Reviews: