12-14
+371 29114991
www.linergo.lv
1.2 Manual Reset
If a motor or other electronic has been disconnected from the column, during or after the
assembly, a reset (homing) cycle MUST be performed. A reset cycle should be made with
an evenly distributed weight of approx. 45 kg (100 lbs) applied on the desk.
Perform a reset by:
Simultaneously pressing the up and down buttons for minimum of
8 seconds.
Press and hold the down button and the desk will slowly move the
lowest point possible.
The desk/stand is ready for normal use.
2. MAINTENANCE & REPAIRS
2.1 Cleaning, Inspection & Storage
Clean the desk stand by wiping it down with a dry micr
ofiber
cloth. Never use solvent,
abrasive or corrosive compounds.
Products must be cleaned at regular intervals to remove dust and dirt and inspected for
mechanical damage and normal wear and tear. Worn-out parts must be replaced.
Unplug the power cord if you do not intend to use the desk for a longer period.
Do not store desk or cables in direct sunlight.
2.2 User Maintenance
Products are closed units and require no internal maintenance. Columns must be
inspected at attachment points, wires, cabinet, and plugs, check that columns function
correctly.
• Inspect columns for loose connections and damaged plugs/wires.
• Inspect control box for loose connections and damaged plugs/wires.
• The power supply and the handset is sealed and maintenance free.
c o m f o r t & e r g o n o m i c s
lin
ergo