background image

 

 

 

 

LE590-TAP 

User’s Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<2nd>

 

Summary of Contents for LE590-TAP

Page 1: ...LE590 TAP User s Manual 2nd...

Page 2: ...4 Control 11 2 1 4 1 Capture Forward 11 2 1 4 3 Auto Save 12 2 1 5 Languages 12 2 1 6 Help 13 2 2 Tool Bar 14 2 2 1 Reconnect 14 2 2 2 Counter 14 2 2 3 USC A USC B 15 2 2 4 Chart 16 2 2 5 Port AB 19 2...

Page 3: ...hile dealing with large quantity of packets 1 1 Hardware Installation Before starting LE590 TAP your PC and LE 590TX shall be connected properly The figure down below illustrates connecting PC and LE...

Page 4: ...o Mode However please note that Demo Mode is for system demo purposes only and does not serve any testing purposes at all When your PC cannot detect your LE 590TX a window as shown above will pop up a...

Page 5: ...ew Counter USC A B and Charts C Information Field In the Information Field you can view system information making port configurations or view port and USC status on right side Main Display Screen D Co...

Page 6: ...Configuration from the Menu Bar All configuration files are saved in the format of xml Save current configuration The Save current configuration function on the Menu Bar allow you to save the setting...

Page 7: ...turn ON the Flow Control the Rate Control settings will be available And when you turn On the Rate Control you may set the Rate between 0 00 1000 00 Mbps After finishing the settings please click App...

Page 8: ...ap After finishing the settings please click Apply button to save the configuration 2 1 2 4 Options Options In this window you can set if the future warning window will pop up more often by choosing t...

Page 9: ...e Update button allows you to pause or start the counter operation If the Update button is shown as the figure on the left than the counter operation is paused If the Update button is shown as the fig...

Page 10: ...er chosen in port configuration for more detail about how to set the parameter to be presented on Alarm Report window please refer to the 2 2 5 Port AB Alarm The Save button allows you to save the Ala...

Page 11: ...kets 16384 packets for one port Set the maximum packets in the Capture Packet Number in the Capture Criteria Instant Received packets are immediately forwarded to the PC via USB It is possible to chec...

Page 12: ...folder in each 60 min Alarm Report Click this option to auto save Alarm Report to the Report folder below your LE590 TAP folder in each 60 min Auto Save Setting 2 1 5 Languages Languages English Simpl...

Page 13: ...dow will pop up and show the requirements for your PC FPGA Firmware AP and API version of the equipment OK Click this button to exit the System Requirements pop up window LINEEYE Web Open your default...

Page 14: ...ction between your PC and LE 590TX is down a Disconnected icon will be shown in System Connection Status Press Reconnect button to re establish the connection between your PC and LE 590TX If the conne...

Page 15: ...indow you may modify the Rule Stream Counter Mode of USC The chosen mode will be shown in the side pointed by the red arrow Click the Apply button to save this setting or Cancel to close this window w...

Page 16: ...n Mbps in D field If you set in Auto mode the Rate will be set under a default setting if you set in User Define mode than a Minimum and a Maximum rate range will be available to modify You can open a...

Page 17: ...zed in Mbps in C field If you set in Auto mode the Rate will be set under a default setting if you set in User Define mode than a Minimum and a Maximum rate range will be available to modify You can o...

Page 18: ...PAUSE You can set the Rate of packets to be analyzed in Mbps in C field If you set in Auto mode the Rate will be set under a default setting if you set in User Define mode than a Minimum and a Maximu...

Page 19: ...d fix the transfer rate in 10 100M under Full duplex You can also set MDIX mode here and click the Set button to save settings made for MDIX mode If you set Auto MDIX mode the LE590 TAP will auto sens...

Page 20: ...s 20 16384 in the Capture Packet Number if the Capture Forward setting is Block SDFR Self Discover Filtering Rules If you closed the Capture all packets function in the Protocol interface the SDFR int...

Page 21: ...nd null DA destination address packets of incoming data streams and then resends them back to the same connected port If you choose the Layer 2 Loopback Mode on Loopback interface the LE 590TX filters...

Page 22: ...r decrease the value of threshold as the limit to starting the alarm report When the network traffic flows through this device and the network event triggers the alarm threshold the alarm condition is...

Page 23: ...23 Website www lineeye com 2 3 System Info Configuration List The System Info Configuration List allows you to view system information and making port configurations...

Page 24: ...com 2 3 1 System Information By clicking the System Information on the System Info Configuration List the System Information screen will be shown on the Main Display Screen located on the right side o...

Page 25: ...st the Port A Port B Configuration screen will be shown on the Main Display Screen located on the right side of LE590 TAP main window allowing you to make settings for LE 590TX ports Those settings in...

Page 26: ...u to make settings for LE 590TX ports Those settings include the Media Type Capture Criteria Loopback and Alarm related to and Besides the change on the status of Media Type Capture Criteria Loopback...

Page 27: ...kets capture operation by clicking the Stop Capture button C In this field you can check the status of each captured packet based on the order of packet No Delta Time us Length with CRC Destination So...

Page 28: ...con 2 4 1 For TAP mode The Control Buttons allow you to start stop tasks and the Operating Status Icon indicates if there s a task running Control Buttons Start task Stop task Operating Status Icon No...

Page 29: ...29 Website www lineeye com Operating Status Icon Not operating Operating...

Page 30: ...4F Marufuku Bldg 39 1 Karahashi Nishihiragaki cho Minami ku Kyoto 601 8468 Japan Phone 81 75 693 0161 Fax 81 75 693 0163 URL https www lineeye com M 29590TAPE LE...

Reviews: