Operation attention

1. Dial REC message switch in rear panel to 1, 2, 3, which means 1, 2, 3 storage. Press 

REC, the indicator will be active, input signal to MIC port, start record. Press stop, it will stop 

record (it should be recorded mAX audio 1 minute for every storage. It can use the recorded 

alarm message in N°3 storage)

2. Start play storage 1 or 2. Separately short circuit COM-NO1 / COM-NO2 of PLAY message, 

simultaneously press PLAY, the indicator will be active, then start play, press STOP, then it 

stops.

3. Press STOP, it can stop record / play. Choose MESSAGE 1 TIME / CONTINUOUS, which 

means play record once / play continuously. Move switch REC message to off, then it can 

not record.

Guidance of excluding errors

Mute function

Test 3 levels priority function :

1. Built in REC MSG (NO.1 and NO.2) priority : TUNER, CD, MP3.

2. Built in chime : REC MSG (NO.1 and NO.2) : TUNER, CD, MP3.

3. Paging MIC first priority than all other music sources.

Phenomena

Cause

All the wires are connected well but no 

voice output

1. No power or wrong plug connection.

2. Fuse is burned.

3. Volume is town off.

4. No input signal.

Power on but alarming signal

1. Overloading or short circuit.

2. Voltage is not stable, too high or low.

No voice output in

1. Machine is in protection condition  in 

case of high temperature.

2. Wrong wire connection.

Network connection line

 

5. OPERATION

 

6. CONNECTIONS

Summary of Contents for LTS.PM62

Page 1: ...0 4 77 81 49 49 Fax 33 0 4 77 81 49 40 www lineartech fr V 2017 Please follow the instructions in this manual to obtain the optimum results from this unit We also recommend that you keep this manual h...

Page 2: ...enclature and functions a Front panel b Rear panel 5 Operation 6 Connections 7 Applications 8 Address set 9 Block diagram 10 Specifications 11 Dimensional diagram Page 3 Page 5 Page 5 Page 5 Page 7 Pa...

Page 3: ...t in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid elect...

Page 4: ...onnect the power supply plug from the AC outlet and contact your nearest dealer Make no further attempt to operate the unit in this conditions this may cause fire or electric shock To prevent a fire o...

Page 5: ...aces such us mosques schools hotels and factories to train stadium and air stations 6 zones sources selection and control function Build in 3 record storage can setting freely to play Build in chime g...

Page 6: ...sage plays continuously till the message contact is kept closed 25 MICROPHONE ALARM NORMAL SWITCH The mixer could work without microphone console a simple microphone base with priority contact be conn...

Page 7: ...UOUS which means play record once play continuously Move switch REC message to off then it can not record Guidance of excluding errors Mute function Test 3 levels priority function 1 Built in REC MSG...

Page 8: ...8 Net production line method 1 amplifier for music 1 amplifier for voice for 6 zone A B 1 Blue 2 White blue 3 Brown 4 White brown 5 Orange 6 White orange 7 Green 8 White green 7 APPLICATIONS...

Page 9: ...9 6 amplifiers one for each zone...

Page 10: ...10 8 ADDRESS SET ID console address set...

Page 11: ...11 ID console address set...

Page 12: ...12 9 BLOCK DIAGRAM...

Page 13: ...B 1 microphone input Phantom power 48V Tuner and tape input sensitivity impedance 200 mV 47 Kohm CD input sensitivity impedance 500 mV 47 Kohm S N ratio 90 dB Frequency response 40 20 000 Hz 3 dB Bass...

Page 14: ...Linear Technologie 11 rue du Puits Rochefort 42 100 Saint Etienne T l 33 0 4 77 81 49 49 Fax 33 0 4 77 81 49 40 www lineartech fr...

Reviews: