DC1304 QUICK START GUIDE 

 

 

 

  

Q U ICK TEST SETU P

Q U ICK TEST SETU P

Q U ICK TEST SETU P

Q U ICK TEST SETU P    –

––

– PAR ALLEL CO N TR O L

 PAR ALLEL CO N TR O L

 PAR ALLEL CO N TR O L

 PAR ALLEL CO N TR O L

    

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Q U IC K  T E S T  P R O C E D U R E  

 

Test Proc

Test Proc

Test Proc

Test Proceeeedure

dure

dure

dure    

 

1.

 

Connect DC1304 as show n, turn on pow er and adjust 

the R BIAS1 pot for 50M H z. 

2.

 

Connect 50 ohm terminator to AIN-(J2) and sinew ave 

generator to AIN + (J1). 

3.

 

Connect oscilloscope to VO UTA+ and on the oscillo-

scope display must show  a 1Vp-p sinew ave. 

4.

 

 Connect oscilloscope to VO UTA- and on the oscillo-

scope display must show  a 1Vp-p sinew ave. 

5.

 

Connect 50 ohm terminator to BIN-(J2) and sinew ave 

generator to BIN + (J1). 

6.

 

Connect oscilloscope to VO UTB+ and on the oscillo-

scope display must show  a 1Vp-p sinew ave. 

7.

 

Connect oscilloscope to VO UTB- and on the oscillo-

scope display must show  a 1Vp-p sinew ave. 

 

 