background image

Beep Sounds During Auxiliary Relay 

Default: No

Selects whether or not the keypad beeps during Auxiliary Relay activation.

Press:

  

4 2 #

 

Sound

 

#

Sound

 = 1 for Yes, = 0 for No

Beep Sounds During Output #3 

Default: No

Selects whether or not the keypad beeps during Output #3 activation.

Press:

  

4 3 #

 

Sound

 

#

Sound

 = 1 for Yes, = 0 for No

Beep Sounds During Output #4 

Default: No

Selects whether or not the keypad beeps during Output #4 activation.

Press:

  

4 4 #

 

Sound

 

#

Sound

 = 1 for Yes, = 0 for No

Keypad Lockout Count 

Default: 3 Tries

Sets the number of incorrect entry code attempts allowed before the keypad 
“locks out”.

Press:

  

5 0 #

 

Attempts

 

#

Attempts

 = Number of attempts before lockout (2-7)

Anti-passback Time 

Default: No Anti-passback

Sets the length of time an entry code will not function after it is used.

Press:

  

5 1 #

 

Minutes

 

#

Minutes

 = Time in Minutes (1-4), 0 = No Anti-passback

RESETTING KEYPAD

Master Reset

  CAUTION: Performing a master reset will clear the 

entire memory of the AK-3 and return all programmable 
options to the factory default values. ALL ENTRY 
CODES WILL BE ERASED.

STEP 1

  Disconnect power from the keypad.

STEP 2

  Press and hold down the 

*

 and # keys.

STEP 3

  Apply power to the keypad, continue holding the keys 

down until the red indicator starts fl ashing.

STEP 4

  Release the keys. The red and yellow indicators will 

remain lit until the process is complete, then the yellow 
indicator will go out.

Resetting the Master Code

STEP 1

  Open the AK-3 case.

STEP 2

  Locate jumper at P2. This jumper is used to reset the 

master code.

STEP 3

  With power applied to the keypad, remove hte jumper 

at P2. The keypad will begin to beep, signaling that the 
code has been reset.

STEP 4

  Replace jumper on P2.

THE MASTER PROGRAMMING CODE IS NOW 123456.

AK-3 OPERATION

Keypad users request access by entering their code.

  Users of the AK-3 have up to 40 seconds to key in their 

entry code.

  Up to eight seconds are allowed between each keystroke.

  All digits of the entry code must be entered. Example: If the 

code is 0042, the user must enter
“0 0 4 2”.

  If the wrong key is pressed, pressing the 

*

 key will reset the 

keypad. The correct code can then be re-entered.

❑ 

After a correct code is entered, the red indicator will turn 
green and the programmed relay will activate for the 
programmed time.

  If the number of incorrect codes entered exceeds the 

keypad lockout count, the yellow indicator will light, 
indicating that the keypad is locked out. The lockout will 
remain for one minute.

  After a valid code has been entered, it will be unusable until 

the anti-passback time expires.

SPECIFICATIONS

MECHANICAL

 

Dimensions:  3.00” W x 5.00” H x 3.00” D

ELECTRICAL

 

Voltage:  12-24 Volts AC or DC

 

Current:  30 mA typical, 150 mA maximum

 Outputs: 

Main 

Relay:

 

    Form “C” 5 Amps @ 28 Volts maximum

  

Auxiliary 

Relay:

 

    Form “C” 1 Amp @ 28 Volts maximum

 

  Solid state outputs (Outputs #3 & #4):

 

    Short-to-common 100 mA @ 24 VDC maximum

ENVIRONMENTAL

 

Temperature:  -22°F to 149°F (-30°C to 65°C)

 

Humidity:  5% to 95% non-condensing

LINEAR LIMITED WARRANTY

This Linear product is warranted against defects in material and workmanship for twenty-
four (24) months. The Warranty Expiration Date is labeled on the product. This warranty 
extends only to wholesale customers who buy direct from Linear or through Linear’s normal 
distribution channels. Linear does not warrant this product to consumers. Consumers 
should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. 

There are no obligations or liabilities on the part of Linear LLC for consequential 
damages arising out of or in connection with use or performance of this product 
or other indirect damages with respect to loss of property, revenue, or profi t,  or 
cost of removal, installation, or reinstallation.

 

All implied warranties, including implied 

warranties for merchantability and implied warranties for fi tness, are valid only until 
Warranty Expiration Date as labeled on the product. 

This Linear Corporation Warranty is 

in lieu of all other warranties express or implied.

All products returned for warranty service require a Return Product Authorization Number 
(RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other 
important details.

FCC NOTICE

Changes or modifi cations not expressly described in this manual or approved by the 
manufacturer could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the user 
is encouraged to try to correct the interference by one or more of the following measures:

•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect the equipment into an outlet on a circuit different from that to 

which the receiver is connected.

•  Consult the dealer or an experienced radio/TV technician for help.

221025 B     IMAGE 8

Copyright © 2004 Linear LLC 

221025 B

Summary of Contents for Digital Keyless Entry System AK-3

Page 1: ...587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com 221025 B IMAGE 1 PRINTER S INSTRUCTIONS INSTR INSTL AK 3 LINEAR P N 221025 B INK BLACK MATERIAL 20 LB MEAD BOND SIZE 8 500 X 11 000 SCALE...

Page 2: ...ramming even without power An internal jumper is provided to reset the master code The Main Relay has a 5 Amp capacity The Auxiliary Relay has a 1 Amp capacity Two solid state outputs capable of switc...

Page 3: ...MPS 28 VDC MAX AUXILIARY RELAY 1 AMP 28 VDC MAX TERMINAL BLOCK 1 WIRES AK 3 TERMINALS CAUTION IF THE UNIT IS AC POWERED MAKE SURE THE SECONDARY OF THE SYSTEM TRANSFORMER IS ISOLATED FROM EARTH GROUND...

Page 4: ...ll Screw the mounting plate onto the electrical box see Figure 4 Final Keypad Installation After wiring the keypad see next page complete the installation by securing the keypad to the mounting plate...

Page 5: ...switch to the keypad box Connect the door switch to the keypad s SENSE terminal gray wire E8 and COM terminal any black wire If an inhibit switch or timer is going to be used for temporarily disabling...

Page 6: ...1 Code Code Relay Code The new entry code 1 999999 depending on code length Relay Relay output entry code will activate 1 Main Relay 2 Auxiliary Relay 3 Both Relays The yellow indicator will flash qui...

Page 7: ...tput activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 1 3 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3...

Page 8: ...Volts AC or DC Current 30 mA typical 150 mA maximum Outputs Main Relay Form C 5 Amps 28 Volts maximum Auxiliary Relay Form C 1 Amp 28 Volts maximum Solid state outputs Outputs 3 4 Short to common 100...

Reviews: