Adding a New Entry Code

Press:  0 1 # Code # Code # Relay #

Code = The new entry code: 1-999999, depending on code length

Relay = Relay output entry code will activate:

1 = Relay #1    2 = Relay #2    3 = Both Relays

The yellow indicator will fl ash quickly while the AKR-1 searches its memory for 
available space and duplicate entries. The green indicator will light when the new 
code is stored.

If the new entry code chosen is already being used for another entry code, the red 
indicator will light. A new unique code needs to be entered.

  NOTE: Leading zeros (zeros before the code number, i.e. 0001) do not need to be entered 

when programming a new entry code. The AKR-1 will internally add any zeros to fi ll all 
digits determined by the entry code length setting. Leading zeros 

will

 have to be entered by 

the user when entering their code to gain access.

Erasing a Single Entry Code

Press:  0 2 # Code # Code #

Code = The entry code to delete.

The yellow indicator will fl ash quickly while the AKR-1 searches its memory for the 
code to erase. The green indicator will light when the code is erased.

Erasing All Entry Codes

  WARNING: Performing this command will remove all 

entry codes from the memory.

Press:  9 7 # 0 0 0 0 0 0 # 0 0 0 0 0 0 #

  NOTE: The green indicator will light while the memory is being erased. This may take up 

to 15 seconds.

Changing the 6-Digit Master Programming Code

Press:  9 8 # Master Code # Master Code #

Master Code = The new 6-digit Master Programming Code

New master code: _____________________

PROGRAMMING OPTIONS

There are several AKR-1 programming options. For most installations, the factory 
set default options are suffi cient. The keypad must be in Programming Mode to 
make these changes.

Programming AKR-1 to Hold the Output

Linear’s AccessKey products have a programmable “Toggle Mode” available for 
each relay and solid-state output. When an output is programmed for Toggle Mode, 
the output alternates from OFF to ON or from ON to OFF each time it is activated. 
The rules for a toggle output are:

•  If the output is OFF, it will turn ON and stay on until the next activation.
•  If the output is ON, it will turn OFF and stay off until the next activation.

Typical Programming

With the unit in Program Mode, set the Auxiliary Relay (Relay #2) output to Toggle 
Mode using the following keystrokes:

Press: 2 2 # 9 9 #

22 = Programming Step; 99 = Toggle Mode

Program all normal entry codes to use the Main Relay (Relay #1), and only 
Relay #1 as the output relay. Program the code(s) that you want to use to hold the 
output for an indefi nite period to the Auxiliary Relay (Relay #2). See the following 
example that sets entry codes 1234 for normal and 5678 for toggle operation.

Press: 0 1 # 1 2 3 4 # 1 2 3 4 # 1 #

01 = Programming Step; 1234 = Entry Code; 
1 = Main Relay

Press: 0 1 # 5 6 7 8 # 5 6 7 8 # 2 #

01 = Programming Step; 5678 = Entry Code; 
2 = Auxiliary Relay

217350 D     IMAGE 10

5678

TOGGLE

ENTRY CODE

1234

NORMAL

ENTRY CODE

Summary of Contents for AKR-1

Page 1: ...ctions 760 438 7000 FAX 760 438 7043 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com 217350 D IMAGE 1 PRINTER S INSTRUCTIONS INSTR INSTL AKR 1 LINEAR P N 217350 D IN...

Page 2: ...s the keys for two minutes after any key is pressed An internal sounder beeps when each key is pressed and when a transmitter is granted access An internal jumper sets the sounder volume high or low T...

Page 3: ...GROUND terminal to a good earth grounding point Suggested wiring size is 18 AWG for earth ground and power up to 500 feet of 18 AWG wire can be run for power use larger wire for longer runs Use 22 AW...

Page 4: ...ER ACCESS INDICATOR NIGHT LIGHT TACTILE KEYPAD YELLOW LOCKOUT INDICATOR KEYLOCK JUMPER JP1 REMOVE TO REDUCE BEEPER SOUND JUMPER JP2 REMOVE TO RESET MASTER CODE TERMINAL BLOCK ANTENNA HIDDEN Figure 1 C...

Page 5: ...RATOR INHIBIT TIMER OPEN FIRE ACCESS ELECTRIC DOOR STRIKE DOOR SWITCH ALARM CONTACT OPTIONAL WIRING REQUIRED WIRING TO ALARM SYSTEM TRANSFORMER ISOLATED AUXILIARY POWER CAUTION IF THE UNIT IS AC POWER...

Page 6: ...to a wall or flat surface Use the appropriate fasteners to secure the keypad s backplate to the mounting surface When mounting the keypad to a concrete wall use concrete wedge anchors or molly anchor...

Page 7: ...ed route two wires from the keypad to the normally open switch Connect the wires to the normally open switch and to the keypad s REQUEST TO ENTER and COMMON terminals If an inhibit switch or timer is...

Page 8: ...res from the keypad to the normally open switch Connect the wires to the normally open switch and to the keypad s REQUEST TO ENTER and COMMON terminals To use the door sense feature to detect forced e...

Page 9: ...r a programming option number is entered the yellow indicator will blink This shows that the AKR 1 is ready to accept the new programming data After the new data entry is complete the green indicator...

Page 10: ...r Programming Code Press 9 8 Master Code Master Code Master Code The new 6 digit Master Programming Code New master code _____________________ PROGRAMMING OPTIONS There are several AKR 1 programming o...

Page 11: ...rced Entry Output Default Output 3 Sets which output activates if the DOOR SENSE input opens before access is granted This output is not timed Press 1 1 Output Output Output to Activate 0 4 1 Relay 1...

Page 12: ...en triggered Press 2 3 Seconds Seconds Output time in seconds 0 60 99 Toggle mode Solid state Output 4 On time Default 2 Seconds Sets the length of time Output 4 activates when triggered Press 2 4 Sec...

Page 13: ...Technical Services for details on how to suspend reactivate individual transmitters Press 9 0 TX ID Status TX ID 1 65535 Status 0 for Suspend 1 for Reactivate Selecting the Facility Codes Default Ign...

Page 14: ...all transmitters used with the AKR 1 See Figure 7 for transmitter button designations for various models Press 7 4 Output Output Output to Activate 0 3 1 Relay 1 2 Relay 2 3 Both Relays 0 No Output S...

Page 15: ...remove jumper JP2 The keypad will begin to beep signaling that the code has been reset STEP 4 Replace jumper JP2 THE MASTER PROGRAMMING CODE IS NOW 123456 Solid State Outputs The two solid state outp...

Page 16: ...s location remove jumper JP1 see Figure 9 Locking Keypad After the installation is complete Lock the keypad using the keylock see Figure 10 Figure 10 Locking the Keypad Case HOOK KEYPAD ONTO BACKPLATE...

Page 17: ...t the keypad is locked out The lockout will remain for one minute After a valid code has been entered it will be unusable until the anti passback time expires With Wireless Transmitter Activate a wire...

Page 18: ...ery supervisory report The keypad s yellow indicator will blink Tamper Loop Fault If the transmitter case is opened or the safety edge contact becomes defective it will send a tamper loop fault superv...

Page 19: ...ct from Linear or through Linear s normal distribution channels Linear does not warrant this product to consumers Consumers should inquire from their selling dealer as to the nature of the dealer s wa...

Page 20: ...ed by the manufacturer could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of t...

Reviews: