Linear AK-21W Installation And Programming Instructions Download Page 6

4

FACTORY DEFAULTS

MASTER PROGRAMMING CODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123456
ENTRY CODE LENGTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DIGITS
REQUEST-TO-EXIT OUTPUT RELAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MAIN RELAY
ALARM SHUNT OUTPUT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  DISABLED
FORCED ENTRY OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  OUTPUT #3
DOOR AJAR OUTPUT  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  OUTPUT #4
MAIN RELAY ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
AUXILIARY RELAY ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
SOLID STATE OUTPUT #3 ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
SOLID STATE OUTPUT #4 ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 SECONDS
DOWNLIGHT ON TIME  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2 MINUTES
DOOR SENSE/INHIBIT INPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DOOR SENSE
KEYPAD LOCKOUT OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  DISABLED
KEYPAD ACTIVE OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  DISABLED
BEEPER SOUNDS WHEN KEY PRESSED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . YES
BEEPER SOUNDS DURING RELAY #1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
BEEPER SOUNDS DURING RELAY #2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
BEEPER SOUNDS DURING OUTPUT #3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
BEEPER SOUNDS DURING OUTPUT #4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO
KEYPAD LOCKOUT COUNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3 TRIES BEFORE LOCKOUT
ANTI-PASSBACK TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  NO ANTI-PASSBACK
AUTO-RELOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ON

BASIC PROGRAMMING

When the AK-21W is in Programming Mode, both indicators will 
turn off until programming begins. After a programming option 
number is entered the yellow indicator will blink. This shows that the 
AK-21W is ready to accept the new programming data. After the 
new data entry is complete, the yellow indicator will fl ash while 
the data is being stored. The green indicator will light if the data 
is accepted. The red indicator will light if any programming data 
is entered incorrectly, and the command will have to be fully 
re-entered.

Entering Programming Mode

The 6-digit Master Programming Code (default = 123456) is used to enter 
Programming Mode.

Press:

  

# 9 #

 

Master Code

 

Master Code

 = the current 6-digit Master Programming Code

Exiting Programming Mode

Press: 

 

*

 

*

 

#

The red indicator will light after exiting Programming Mode.

 

NOTE: 

The AK-21W will automatically exit Programming Mode after two 

minutes of inactivity.

Re-entering a Command After a Mistake

If the red indicator lights, signaling an incorrect entry, or an incorrect key is 
pressed during programming, to clear the keypad and re-enter the command:

Press: 

 

*

 

9 #

Setting Entry Code Length 

Default: 4 digits

Press:

  

0 3

 

#

 

Length

 

#

Length

 = 1 - 6 for entry code length

 

NOTE: If the Entry Code Length is going to be changed from the factory 
default of four digits, make this change fi rst, before programming any 
entry codes.

Adding a New Entry Code

Press: 

01 # Code # Code # Action #

Code = The new entry code: 1-999999, depending on code length

Action = Relay output entry code will activate as follows:

 

  1 = Relay #1, timed open

 

  2 = Relay #2, timed open

 

  3 = Both Relays, timed open

 

10 = Relay #1, toggled

 

20 = Relay #2, toggled

 

30 = Both Relays, toggled

 

12 = Relay #1 toggled; Relay #2, timed open

 

21 = Relay #1 timed open; Relay #2 toggled

The yellow LED will fl ash quickly while the AK-21W searches its 
memory for available space and duplicate entries. The green LED 
will light when the new code is stored. 
If the new entry code chosen is already being used for another 
entry code, the red LED will light. A new 

unique

 code needs to be 

entered.

☞ 

NOTE:

 Leading zeros (zeros before the code number, i.e. 0001) do not 

need to be entered when programming a new entry code. The AK-21W will 
internally add any zeros to fi ll all digits determined by the entry code length 
setting. Leading zeros 

will

 have to be entered by the user when entering their 

code to gain access.

Erasing a Single Entry Code

Press:

  

0 2 #

 

Code

 

#

 

Code

 

#

Code

 = The entry code to delete.

The yellow indicator will fl ash quickly while the AK-21W searches 
its memory for the code to erase. The green indicator will light 
when the code is erased.

Erasing All Entry Codes

  WARNING: PERFORMING THIS COMMAND WILL 

REMOVE ALL ENTRY CODES FROM THE MEMORY.

Press:

  

9 7 # 0 0 0 0 0 0 # 0 0 0 0 0 0 #

 

NOTE:

 The green indicator will light while the memory is being erased. This 

may take up to 15 seconds.

Changing the 6-Digit Master Programming Code

Press:

  

9 8 #

 

Master Code

 

#

 

Master Code

 

#

Master Code

 = The new 6-digit Master Programming Code

New master code: _____________________

228041 A     IMAGE 6

Summary of Contents for AK-21W

Page 1: ...Entry System 760 438 7000 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com Installation and Programming Instructions For more information please visit www devancocana...

Page 2: ...ains all entry codes and programming even without power An internal jumper is provided to reset the master code The Main Relay has a 5 Amp capacity The Auxiliary Relay has a 1 Amp capacity Two solid s...

Page 3: ...1 12 24 VOLT AC OR DC POWER MAIN RELAY 5 AMPS 28 VDC MAX AUXILIARY RELAY 1 AMP 28 VDC MAX TERMINAL BLOCK 2 TERMINAL BLOCK 1 AK 21W TERMINALS CAUTION IF THE UNIT IS AC POWERED MAKE SURE THE SECONDARY O...

Page 4: ...ower beeper sound level is required before installing the keypad remove Jumper JP1 place the jumper block on one pin to save the jumper Hook the keypad assembly onto the mounting plate tab see Figure...

Page 5: ...s from the switch to the keypad box Connect the door switch to the keypad s SENSE terminal TB1 8 and COM terminal TB1 7 If an inhibit switch or timer is going to be used for temporarily disabling the...

Page 6: ...essed during programming to clear the keypad and re enter the command Press 9 Setting Entry Code Length Default 4 digits Press 0 3 Length Length 1 6 for entry code length NOTE If the Entry Code Length...

Page 7: ...t activates when any keys are pressed This output is timed If toggle mode is selected for the output the timer value defaults to 2 seconds Press 1 4 Output Output Output to Activate 0 4 1 Main Relay 2...

Page 8: ...4 Volts AC or DC Current 30 mA typical 150 mA maximum Outputs Main Relay Form C 5 Amps 28 Volts maximum Auxiliary Relay Form C 1 Amp 28 Volts maximum Solid state outputs Outputs 3 4 Short to common 10...

Page 9: ...PARTS DEVANCO CANADA 19192 HAY ROAD UNIT Q SUMMERSTOWN ON K0C 2E0 TOLL FREE 855 931 3334 www devancocanada com WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION 3 PART NUMBER 3 DESCRI...