background image

(760) 438-7000

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

AE-500

Telephone Entry
& Access Control
System

220793 F     IMAGE 1

PRINTER’S INSTRUCTIONS:

INSTR,INSTL,AE-500 - LINEAR P/N: 220793 F - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH

Installation Instructions

Summary of Contents for AE-500

Page 1: ...760 438 7000 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com AE 500 Telephone Entry Access Control System Installation Instructions...

Page 2: ...TIPLE UNIT SUPPORT Up to seven AE 500 units can be connected on the same telephone line REMOTE KEYPAD SUPPORT The system supports one Linear remote interior or exterior keypad Software Highlights LOCA...

Page 3: ...ith any Internet browser on site using a separate phone line or off site The intuitive graphic display of each of the programming step is the preferred method to program the AE 500 Local Programming A...

Page 4: ...OR POWER INDICATOR MAIN POWER SWITCH RECEIVER RANGE KNOB ANTENNA CONNECTOR MICROPHONE DISPLAY POSTAL LOCK MOUNTING PLATE SPEAKER KEYPAD LIGHTING CONNECTOR MICROPHONE CONNECTOR SPEAKER CONNECTOR JTAG U...

Page 5: ...P EARTH GROUND RING ELECTRIC DOOR STRIKE RELAY RATING 3 AMPS 30 VOLTS AC DC MAXIMUM TELEPHONE JACK DOOR STRIKE POWER SUPPLY DOOR SENSE CONTACT CASE GROUND STUD NOTE OPTIONAL BACKUP BATTERY WILL REQUIR...

Page 6: ...ted from the AE 500 NEVER MOUNT THE UNIT DIRECTLYTO A MOVING DOOR OR GATE Gate Installations If the AE 500 is used to control a gate operator connected to a vehicular gate the unit MUST be mounted AT...

Page 7: ...it board screws Note how the green ground wire lugs are connected with the upper left screw 3 Carefully remove the circuit board Hold it by the edges Set it aside in a safe place Reverse these steps t...

Page 8: ...supplied 8 Replace the circuit board and plug in each wiring connector Be sure to replace the green ground wires Pedestal Mounting The cabinet can be mounted on a standard goose neck pedestal When mou...

Page 9: ...ay Channel A connect the wires to the RTE A and GND terminals 4B To activate Relay Channel B connect the wires to the RTE B and GND terminals Sensing Input The sensing input connects to a door switch...

Page 10: ...Company Alternately connect to a cold water pipe for the earth ground 1 Connect the wire from the earth ground to the AE 500 s CASE GROUND STUD NOTE The EARTH GROUND terminal is internally connected...

Page 11: ...500 The kit contains a whip antenna connector and a 36 length of coax cable The antenna connector should be mounted on a metal surface using a 3 8 hole Two other models of antennas are compatible wit...

Page 12: ...Exterior Keypad The Model AM KP is housed in a rugged cast aluminum enclosure designed for exterior installations The keypad can be mounted to a pedestal or directly to a wall A keylock secures the k...

Page 13: ...ough the AE 500 s programming pages is similar to browsing through your favorite web site s pages Anyone familiar with the Internet will find programming the AE 500 with a computer very easy The AE 50...

Page 14: ...m the telephone s keypad Refer to the following sections of this manual for programming step details When programming over the telephone each programming step consists of entering programming data usi...

Page 15: ...Y LANGUAGE ENGLISH PPN 31 ENTRY CODE RELAY SELECTION RELAY CHANNELS A B PPN 31 ENTRY CODE USAGE LIMIT UNLIMITED PPN 44 TRANSMITTER BUTTON SETUP SINGLE BUTTON LEFT OR TOP LEFT BUTTON ACTIVATES RELAY CH...

Page 16: ...2 3 When the New Connection Wizard asks for the Phone Number to Dial Step 7 in the Page 13 figure enter the common telephone number for the multi unit installation followed by four commas the unit num...

Page 17: ...ying a Resident Once resident data has been set it can be modified to change a resident s name or telephone number 1 If not already in Programming Mode use the local keypad to enter the master passwor...

Page 18: ...1 250 12 Press 13 Exit Programming Mode if all programming is complete Modifying an Entry Code Once entry codes have been set they can be modified to change the relay s to activate or the number of us...

Page 19: ...nsmitter is assigned it will become active and ready to use 1 If not already in Programming Mode connect by telephone or use the local keypad Enter the master password and access programming 2 Press 3...

Page 20: ...nately Relay Channel B can be used for alarm contact shunting obstacle sensing output or triggering audible alarms 1 Press 2 Enter a number for the Relay Channel B function Enter 0 for normal access c...

Page 21: ...lephone or use the local keypad Enter the master password and access programming 2 Press 3 Select the status for the MGT transmitter Enter 1 to activate the transmitter Enter 0 to deactivate the trans...

Page 22: ...ming is complete Speaker Chirp on Keystrokes The factory setting will cause the speaker to chirp when each key on the local keypad is pressed The speaker chirp can be turned off 1 If not already in Pr...

Page 23: ...on 4 button transmitters activate Relay Channel B Top button on 2 or 4 button transmitters is disabled Lower left on 4 button transmitters is disabled Lower right on 4 button transmitters is disabled...

Page 24: ...tch Relay Channel B Press to release Relay Channel A Press to release Relay Channel B 3 The display will show the unit number for three seconds 4 Exit Programming Mode if all programming is complete D...

Page 25: ...ion When calling for technical assistance Linear s Technical Services Department may ask the installer to use these components to diagnose the system On board Indicators Eleven LED indicators are on t...

Page 26: ...facilitate a faster search the directory search will begin in the middle The visitor can search forward or backward from there When the visitor finds the resident s directory number they enter it on...

Page 27: ...n incoming call 1 Automatic telephone answer disabled 2 AE 500 telephone line trouble Entry code will not activate relay 1 Entry code not set up for proper relay Remote keypad does not work 1 Remote k...

Page 28: ...tion Number RPA Contact Linear Technical Services at 1 800 421 1587 for an RPA and other important details FCC Notice Changes or modifications not expressly described in this manual or approved by the...

Reviews: