background image

PAGE 1 

BIASI B/40 

 

 

LINEAR 

6-12 SECTION 

REV. H 

Please Read Instructions Carefully  

Save for Future Reference 

Manufactured by:

Manufactured by:

Manufactured by:

Manufactured by:    

Biasi S.p.A.

Biasi S.p.A.

Biasi S.p.A.

Biasi S.p.A.    

Verona, Italy

Verona, Italy

Verona, Italy

Verona, Italy    

    

Distributed By:

Distributed By:

Distributed By:

Distributed By:    

QHT

QHT

QHT

QHT    

QUINCY HYDRONIC TECH

QUINCY HYDRONIC TECH

QUINCY HYDRONIC TECH

QUINCY HYDRONIC TECHNOLOGY

NOLOGY

NOLOGY

NOLOGY, INC.

, INC.

, INC.

, INC.    

3560 LAFAYETTE RD

3560 LAFAYETTE RD

3560 LAFAYETTE RD

3560 LAFAYETTE RD    

PORTSMOUTH, NH  0380

PORTSMOUTH, NH  0380

PORTSMOUTH, NH  0380

PORTSMOUTH, NH  03801

1

1

1    

PHONE: 603

PHONE: 603

PHONE: 603

PHONE: 603----334

334

334

334----6400

6400

6400

6400    

FAX: 603

FAX: 603

FAX: 603

FAX: 603----334

334

334

334----6401

6401

6401

6401    

B

o

il

er

 M

a

n

u

a

A

n

d

 I

n

st

a

ll

a

ti

o

n

  

In

st

ru

ct

io

n

fo

r

 

A

tm

o

sp

h

er

ic

 V

en

ti

n

g

 

L

IN

E

A

R

 

B

O

IL

E

R

 

If  the  information  in  this  manual  is  not  followed 
exactly,  a  fire  explosion  may  result  causing  property 
damage, personal injury or loss of life. 

WARNING 

WHAT TO DO IF YOU SMELL GAS 

• 

Do not  try to light any appliance 

• 

Do not touch any electric switch; do not use any 
phone in your building 

• 

Immediately call your gas supplier from another 
location.  Follow the gas supplier’s instructions. 

• 

If you can not reach your gas supplier call the 
fire department 

DANGER 

Summary of Contents for 6-12 SECTION

Page 1: ...UTH NH 0380 PORTSMOUTH NH 0380 PORTSMOUTH NH 0380 PORTSMOUTH NH 03801 1 1 1 PHONE 603 PHONE 603 PHONE 603 PHONE 603 334 334 334 334 6400 6400 6400 6400 FAX 603 FAX 603 FAX 603 FAX 603 334 334 334 334...

Page 2: ...lines rather than specific recommendations We realize that other makes and models of such devices are available and can be used as successfully as those we specify The installing contractor is the bes...

Page 3: ...er Location 5 7 Boiler Block Assembly 6 8 Boiler Trim Kit Installation 7 8 Boiler Tapping Diagram 9 Burner Set up 8 10 Gas Piping 9 12 Breeching and Chimney 10 14 Piping 11 15 Boiler Jacket Assembly 1...

Page 4: ...operating properly when the installation is completed Do not burn volatile garbage gasoline naphtha or other flammable liquids other than No 2 fuel oil All flammable liquids especially gasoline chemi...

Page 5: ...g flu season A victim may not experience any symptoms only one symptom or a few symptoms Suspect the presence of carbon monoxide if symptoms tend to disappear when you leave your home The following si...

Page 6: ...ontent Gals Length L inches Weight LBS B40 6 6 265 2 20 308 230 86 0 17 34 8 902 B40 7 7 352 2 90 406 305 86 7 20 39 5 1023 B40 8 8 437 3 60 504 380 86 8 23 44 4 1144 B40 9 9 524 4 30 602 456 87 0 26...

Page 7: ...AL In general boiler rooms should incorporate two 2 permanent air supply openings one commencing within 12 inches of the ceiling and one commencing within 12 inches of the floor These openings should...

Page 8: ...rter draw rods are installed on the bottom of the boiler The bottom draw rods should not extend past the front section Draw the sections together until sections make iron to iron contact at a point ar...

Page 9: ...the location and function of the front and rear boiler tappings Boiler Model Length L B 40 6 34 8 B 40 7 39 5 B 40 8 44 5 B 40 9 49 2 B 4 10 53 9 B 4 11 58 8 B 4 12 63 9 2 5 MPT Return 2 5 MPT Supply...

Page 10: ...L FULL Nozzle 2 00 X 45 2 25 X 60 2 75 X 60 3 25 X 60 3 75 X 60 4 5 X 45 5 50 X 45 Spray Pattern solid solid solid solid solid solid solid Pump Pressure 140 psi 170 psi 175 psi 175 psi 175 psi 160 psi...

Page 11: ...1 Setting the electrode and flame rod settings against manufacturer s specs to insure proper operation 2 Installing properly sized gas piping according to BTU input required and length of gas line ru...

Page 12: ...1 for proper sizing of gas piping for various lengths and diameters Locate a drop pipe adjacent to but not in front of the boiler Locate a tee in the drop pipe at the same elevation as the gas inlet c...

Page 13: ...union 4 A drip pipe Caution The gas valve should not be subjected to more than PSIG Therefore the burner should be isolated during high pressure gas leak tests The appliance and its individual shut o...

Page 14: ...and 400F gross stack temp so caution should be used when connecting to an outside built chimney Should you have concern that the flue gases could condense then you should consider using a listed powe...

Page 15: ...hould be supported by suitable hangars and floor stands not by the boiler It is recommended that the make up water line have a backflow preventer and a pressure reducing valve to reduce line pressure...

Page 16: ...BIASI B 40 PAGE 16...

Page 17: ...nd screw on the threaded hex spacers 87 onto the studs Attach the lower mounting bracket 83 to the boiler by using two bolts 89 and screw ing them into the threaded hex spacers Then using sheet metal...

Page 18: ...er shall come from a dedicated breaker in the electric service box A service switch should be mounted on the side of the boiler so the burner man can service the burner and controls The electrical wir...

Page 19: ...the manual high limit 5 Circulator Switch Supplies power to boiler circulator or relay panel It is not suggested to use this switch and it is not utilized in any of the suggested wiring diagrams in th...

Page 20: ...BIASI B 40 PAGE 20 B 40 Control Panel Wiring Diagram for Beckett Heat Wise Oil Burner 24V CIRCULATOR RELAY BURNER CONTROL...

Page 21: ...PAGE 21 BIASI B 40 B 40 Control Panel Wiring Diagram for Beckett Heat Wise Oil Burner Line Voltage CIRCULATOR RELAY BURNER CONTROL...

Page 22: ...BIASI B 40 PAGE 22 B 40 Control Panel Wiring Diagram for Riello Oil Burner...

Page 23: ...PAGE 23 BIASI B 40 B 40 Control Panel Wiring Diagram for Heat Wise Gas Burners CIRCULATOR RELAY Burner Primary Control...

Page 24: ...he flexible oil line Brush and vacuum combustion chamber and flue passages until all deposits are removed Reassemble components in reverse order making sure any damaged gaskets are repaired or replace...

Page 25: ...________________ ______________________ _________________________ ______________________ Burner Manufacturer Type of Oil Burner Burner Model No Burner Serial No Nozzle Manufacturer Nozzle Spray Angle...

Page 26: ...BIASI B 40 PAGE 26...

Page 27: ...PAGE 27 BIASI B 40...

Page 28: ...lled with approved burner and that installation conforms to all codes and ordinances 4 This warranty does not apply to boilers which are subject to misuse abuse neglect alteration accident excessive t...

Reviews: