measurement equipment anD setup

The LTC5510 is a wideband active mixer IC with very high 

linearity.  Accuracy  of  its  performance  measurement  is 

highly dependent on equipment setup and measurement 

technique. The recommended measurement setups are 

presented in Figure 4, Figure 5 and Figure 6. The following 

precautions should be observed:
1.  Use high performance signal generators with low har-

monic output and low phase noise, such as the Rohde 

&  Schwarz  SME06.  Filters  at  the  signal  generators’ 

outputs may also be used to suppress higher order 

harmonics.

2.  A  high  quality  RF  power  combiner  which  provides 

broadband 50Ω termination on all ports and has good 

port-to-port isolation should be used, such as the Mini-

Circuits ZFSC-2-372-S+.

3.  Use high performance amplifiers with high IP3 and 

high reverse isolation, such as the Mini-Circuits ZHL-

1042J, on the outputs of the RF signal generators to 

improve source isolation to prevent the sources from 

modulating each other and generating intermodulation 

products.

4.  Use attenuator pads with good V

SWR

 on the demon-

stration circuit’s input and output ports to improve 

source and load match to reduce reflections, which 

may degrade measurement accuracy.

5.  A  high  dynamic  range  spectrum  analyzer,  such  as 

the Rohde & Schwarz FSEM30, should be used for 

linearity measurement.

NETWORK

ANALYZER

5V DC 

POWER

SUPPLY

+

50Ω

TERMINATION

50Ω

TERMINATION

Figure 4. Proper Equipment Setup for Return Loss Measurements

Summary of Contents for LTC5510

Page 1: ...anced active mixer with an input buffer and a high speed LO amplifier The mixer can be used for both up and down conversion and requires only 0dBm of LO power to achieve excellent distortion and noise...

Page 2: ...otice Refer to the latest LTC5510 data sheet for the most up to date specifications Performance Summary Specifications are at TC 25 C VCC 5V EN High PLO 0dBm PIN 10dBm 10dBm tone for two tone tests un...

Page 3: ...s shutdown reducing current consumptiontoapproximately1 3mA TheEnablevoltage shouldneverfallbelow 0 3V orexceedthepowersupply voltage by more than 0 3V Temperature Monitor TEMP The LTC5510 s junction...

Page 4: ...ides broadband 50 termination on all ports and has good port to portisolationshouldbeused suchastheMini Circuits ZFSC 2 372 S 3 Use high performance amplifiers with high IP3 and high reverse isolation...

Page 5: ...uation reduces sensitivity and dynamic range 8 Before taking measurements the system performance should be evaluated to ensure that a Clean input signals can be produced The two tone signals OIP3 shou...

Page 6: ...ngs Make all connections with RF and DC power off Return Loss Measurements 1 Configure the Network Analyzer for return loss mea surement set appropriate frequency range and set the test signal to 0dBm...

Page 7: ...MeasuretheresultingoutputontheSpectrumAnalyzer 6 Calculate output 3rd order intercept OIP3 IM3 2 POUT Where IM3 POUT PIM3 POUTisthelowestfundamental output signal power PIM3 is the highest 3rd order...

Page 8: ...2 E3 E4 TESTPOINT TURRET 0 094 MILL MAX 2501 2 00 80 00 00 07 0 6 3 J1 J2 J3 CONN SMA 50 EDGE LAUNCH E F JOHNSON 142 0701 851 7 0 J4 CONN OPTION 8 0 L1 L2 IND 0603 OPTION 9 1 L3 IND 0603 WIRE WOUND 22...

Page 9: ...or Customer Use Only CUSTOMER NOTICE LINEAR TECHNOLOGY HAS MADE A BEST EFFORT TO DESIGN A CIRCUIT THAT MEETS CUSTOMER SUPPLIED SPECIFICATIONS HOWEVER IT REMAINS THE CUSTOMER S RESPONSIBILITY TO VERIFY...

Page 10: ...DING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONS...

Reviews: