Linear Technology LTC4361 Manual Download Page 2

2

dc1506af

DEMO MANUAL DC1506A

QUICK START PROCEDURE

Demonstration circuit description 1506A is easy to set 

up to evaluate the performance of the LTC4361. Refer to 

Figure 2 and Figure 3 for proper measurement equipment 

setup and follow the procedure below.
1.  Connect a power supply across V

IN

 and GND.

2.  Select ENABLE at JP2 to enable the protection.
3. Select protection type at JP1 and connect a load and 

voltmeter across the corresponding output and GND:

    a. For overvoltage and overcurrent protection select  

    (A) OV/OC and connect to OUT(A). Figure 2a.

    b. For overvoltage, overcurrent and negative voltage  

    protection select (B) OV/OC/NV and connect to  

    OUT(B). Figure 2b.

    c. For overvoltage, overcurrent, negative voltage,  

    and reverse current protection select (C) OV/OC/ 

    NV/RC, connect to OUT(C). Figure 2c.

4. For USB protection, connect a USB cable from J2 to 

the USB device (Figure 3). Select the protection type 

at JP1 and match JP3 to JP1. Connect a second USB 

cable from a computer to J1.

Table 1. Typical DC1506A Performance Summary (T

A

 = 25°C)

PARAMETER

CONDITION

VALUE

Input Voltage

Protection (A) OV 

Protection (B) OV/OC/NV 

Protection (C) OV/OC/NV/RC

0V to 30V 

–30V to 30V 

–30V to 30V

Output Voltage

Input Range for Gate Turn-On

2.1V to 5.8V

Overcurrent Threshold

51mΩ Sense Resistor

980mA

Overcurrent Retry

Protection (A) OV/OC, LTC4361-1 

Protection (B) OV/OC/NV, LTC4361-2 

Protection (C) OV/OC/NV/RC, LTC4361-1

Latchoff 

Auto-Retry 

Latchoff

PERFORMANCE SUMMARY

Summary of Contents for LTC4361

Page 1: ...ustable dV dt ramp up for inrush current limiting A PWRGD pin provides power good monitoring for VIN The LTC4361 L LT LTC LTM Linear Technology and the Linear logo are registered trademarks of Linear...

Page 2: ...lect B OV OC NV and connect to OUT B Figure 2b c For overvoltage overcurrent negative voltage and reverse current protection select C OV OC NV RC connect to OUT C Figure 2c 4 For USB protection connec...

Page 3: ...EMO MANUAL DC1506A QUICK START PROCEDURE Figure 2a DC1506A Protection A Setup for Overvoltage and Overcurrent SELECT PROTECTION A OVERVOLTAGE OVERCURRENT PROTECTED OUT 1506a FO2a SELECT ENABLE PWRGD V...

Page 4: ...06A Protection B Setup for Overvoltage Overcurrent and Negative Voltage QUICK START PROCEDURE SELECT PROTECTION B 1506a FO2b SELECT ENABLE VIN OVERVOLTAGE OVERCURRENT NEGATIVE VOLTAGE PROTECTED OUT PW...

Page 5: ...af DEMO MANUAL DC1506A QUICK START PROCEDURE Figure 3 DC1506A USB Protection Setup SELECT PROTECTION SELECT USB PROTECTION JP3 MUST MATCH JP1 USB CABLE 1506a FO3 SELECT ENABLE USB DEVICE USB CABLE HOT...

Page 6: ...nt negative voltage connection at the input A Kelvin sense to the sense resistor in series with the power path provides overcurrent detection In the case of an overcurrent the LTC4361 2 used in protec...

Page 7: ...ng patent rights SCHEMATIC DIAGRAM 5 5 4 4 3 3 2 2 1 1 D D C C B B A A REVISION HISTORY DESCRIPTION DATE APPROVED ECO REV REVISION HISTORY DESCRIPTION DATE APPROVED ECO REV REVISION HISTORY DESCRIPTIO...

Page 8: ...UDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CON...

Page 9: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Analog Devices Inc DC1506A...

Reviews: